NOTE: Proper capacitor polarity must be noted when
attaching the capacitor to the Switch Board assembly.
6.
Install the new Capacitor and tighten the two bolts
to a torque of 55 inch-pounds (6 Nm). Hand tight-
en first, then tighten the bolts in increments of 10
inch-pounds, alternating between the two. See
Figure F.27.
7. Tighten the set screw of the clamping ring
8.
Perform the Test After Repair of Switch Boards