V300-I
TROUBLESHOOTING & REPAIR
7. Test for 0 VDC between leads 311 and 313 on
Protection Board.
a. If 0-1 VDC is present, the Protection Board is
OK. Go to step 8.
b. If 15 VDC is present, go to step 11.
F-40