background image

English  

English 

1

Technical Specifications 

 

NAME 

INDEX 

INVERTEC

®

 PC208 CE 

K12037-1 

INVERTEC

®

 PC208 AUS 

K12037-2 

INVERTEC

®

 PC210 CE 

K12038-1

 

INVERTEC

®

 PC210 AUS 

K12038-2 

INPUT 

Input Voltage 

Input Power at Rated Output 

EMC Class 

Frequency 

230 V ±10%  

Single Phase 

2 kW @ 100% Duty Cycle 

A 50Hz 

2.5 kW @ 60% Duty Cycle 

3 kW @ 35% Duty Cycle 

RATED OUTPUT AT 40°C 

Duty Cycle 

(Based on a 10 min. period)

 

Output Current 

Output Voltage 

100% 

15 A 

86 Vdc 

60% 

20 A 

88 Vdc 

35% 

25 A 

90 Vdc 

OUTPUT RANGE 

Cutting Current Range 

Maximum Open Circuit Voltage 

Pilot Arc Current 

10 - 25 A 

500 Vdc 

12 A 

EXTERNAL INLET COMPRESSED AIR 

Required Inlet Flow Rate 

Required Inlet Pressure 

80 ±20% l/min @ 5.0bar 

6.0bar - 7.5bar 

RECOMMENDED INPUT CABLE AND FUSE SIZES 

Fuse (delayed) or Circuit Breaker 

(“D” characteristic) Size

 

Type of Plug 

(Included with Machine) 

Input Power Cable 

16 A 

SCHUKO 16A / 250V 

3 x 1.5 mm

2

 

AUSTRALIAN 15A / 250V 

PHYSICAL DIMENSIONS 

Height Width 

Length 

(case only,without torch) 

Weight 

385 mm 

215 mm 

480 mm 

18 – 18.5 kg 

 

Operating Temperature 

Storage Temperature 

-10°C to +40°C 

-10°C to +40°C 

 

Summary of Contents for INVERTEC PC208 AUS

Page 1: ...IM2016 01 2021 REV09 INVERTEC PC208 PC210 OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 260 Bielawa Poland www lincolnelectric eu ...

Page 2: ...erence record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDEX Technical Specifications 1 ECO design information 2 Electromagnetic Compatibility EMC 4 Safety 5 Installation and Operator Instructions 7 WEEE 12 Spare Parts 12 REACh 12 Authorized Service ...

Page 3: ...6 Vdc 60 20 A 88 Vdc 35 25 A 90 Vdc OUTPUT RANGE Cutting Current Range Maximum Open Circuit Voltage Pilot Arc Current 10 25 A 500 Vdc 12 A EXTERNAL INLET COMPRESSED AIR Required Inlet Flow Rate Required Inlet Pressure 80 20 l min 5 0bar 6 0bar 7 5bar RECOMMENDED INPUT CABLE AND FUSE SIZES Fuse delayed or Circuit Breaker D characteristic Size Type of Plug Included with Machine Input Power Cable 16 ...

Page 4: ...de STICK mode After 30 minutes of non working X Fan off The value of efficiency and consumption in idle state have been measured by method and conditions defined in the product standard EN 60974 1 20XX Manufacturer s name product name code number product number serial number and date of production can be read from rating plate XXXXXXXXXX Code XXXXX XXXXXX X S N P1YYMMXXXXX 1 2 3 4 5 P1 YY MM XXXXX...

Page 5: ... process gas usage depends on cross sectional area of the nozzle For comonnly used torches Helium 14 24 l min Argon 7 16 l min Notice Excessive flow rates causes turbulence in the gas stream which may aspirate atmospheric contamination into the welding pool Notice A cross wind or draft moving can disrupt the shielding gas coverage in the interest of saving of protective gas use screen to block air...

Page 6: ...levision transmitters and receivers Computers or computer controlled equipment Safety and control equipment for industrial processes Equipment for calibration and measurement Personal medical devices like pacemakers and hearing aids Check the electromagnetic immunity for equipment operating in or near the work area The operator must be sure that all equipment in the area is compatible This may req...

Page 7: ...in accordance with local electrical regulations ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker shall consult their physician before operating this equipment CE COMPLIANCE This equipment complies with the European Community Directives AR...

Page 8: ...ct input plug or power before working on machine Breathing cutting fumes can be hazardous to your health Keep your head out of the fumes Use forced ventilation or local exhaust to remove the fumes Use ventilating fan to remove fumes Arc rays can burn eyes and injure skin Wear hat and safety glasses Use ear protection and button shirt collar Use welding helmet with correct shade of filter Wear comp...

Page 9: ... from the input connection is adequate for normal operation of the machine The fuse rating and cable sizes are both indicated in the technical specification section of this manual The machines PC208 230Vac 50Hz single phase PC210 230Vac 50Hz single phase are designed to operate on engine driven generators as long as the auxiliary can supply adequate voltage frequency and power as indicated in the ...

Page 10: ...nternal External air selection PC210 only This switch determine the air supply With the In Compr position selected the machine operates through the built in compressor With the Ext Air position selected the internal compressor is completely disabled and the machine operates through an external air supply hose connected to the proper air inlet connection placed on the machine rear side WARNING PC21...

Page 11: ...to the vertical position as the arc becomes deeper Once the work piece is pierced normal cutting can occur Keep moving while cutting and cut at a steady speed so that the arc leg is 10 to 20 behind the travel direction Use a 5 to 15 leading angle in the direction of the cut Once the cutting process is terminated releasing off the torch button will cause the plasma arc to be turned off the air flow...

Page 12: ...based on tests performed on an automatic test bench the best results however can only be achieved from direct experience by the operator in his actual working conditions PC208 PC210 internal air PC210 external air Speed cm min Speed cm min Thickness Current A MILD STEEL ALUMINUM STAINLESS STEEL Current A MILD STEEL ALUMINUM STAINLESS STEEL 4 mm 25 147 94 77 7 25 179 122 112 8 5 mm 25 108 86 59 25 ...

Page 13: ...for any customer s particular purpose with respect to such information or advice As a matter of practical consideration we also cannot assume any responsibility for updating or correcting any such information or advice once it has been given nor does the provision of information or advice create expand or alter any warranty with respect to the sale of our products Lincoln Electric is a responsive ...

Page 14: ... First read the Part List reading instructions above then refer to the Spare Part manual supplied with the machine that contains a picture descriptive part number cross reference REACh 11 19 Communication in accordance with Article 33 1 of Regulation EC No 1907 2006 REACh Some parts inside this product contain Bisphenol A BPA EC 201 245 8 CAS 80 05 7 Cadmium EC 231 152 8 CAS 7440 43 9 Lead EC 231 ...

Reviews: