TWIST-MATE CABLE PLUG INSTALLATION INSTRUCTIONS

TURN THE POWER SWITCH OF THE WELDING POWER
SOURCE "OFF" BEFORE INSTALLING PLUGS ON CABLES
OR WHEN CONNECTING OR DISCONNECTING PLUGS TO
WELDING POWER SOURCE.

1.

WELDING CABLE

BOOT

TRIM

Slide the copper tube into the brass plug.

Insert cable into copper tube.

COPPER TUBE

Slide rubber boot over brass plug. The rubber boot must be 

positioned to completely cover all electrical surfaces after

the plug is locked into the receptacle.

SET SCREW

BRASS PLUG

BOOT MARKING

2

2

50-70

70-95

CABLE SIZE

1/0-2/0

CABLE SKIN LENGTH

1 INCH (25.4mm)

2.

2/0-3/0

50-70

70-95

mm )

mm )

(

(

AMERICAN (EUROPEAN) RANGE

CHECK THAT THE CONNECTOR BOOT IS MARKED FOR THE

APPROPRIATE CABLE SIZE PER TABLE BELOW; AND

SKIN CABLE JACKET TO LENGTH SPECIFIED:

1 INCH (25.4mm)

35-50

2

mm )

( 35-50

#2-#1

TWIST-MATE WELDING CABLE PLUG INSTALLATION INSTRUCTIONS

 9-20-91J 

1.5 INCH (38.1mm)

must apply firm pressure against welding cable. The top of the

(70-95 size may

have 2 set
screws)

SEE

ABOVE

Tighten set screw(s) to collapse copper tube. Screw(s)

 brass plug after tightening.

set screw(s) will be nearly flush or below the surface of the

7.

6.

5.

4.

3.

Slide rubber boot onto cable end.

If necessary, trim cable end of boot at groove(s) to match cable

diameter. Boot must fit tightly enough to seal around outside

 different cable diameters without trimming. These boots do not

based lubricant will help to slide the boot over the cable.

have grooves at the cable end. Soap or other non petroleum

diameter of cable.  NOTE:  Some boots are designed to accommodate

S18737 

Summary of Contents for IDEALARC CV-400-I

Page 1: ...PERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT And most importantly think before you act and be careful For use with machine Code Numbers 1...

Page 2: ...WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy of...

Page 3: ...ical earth ground 3 f Maintain the electrode holder work clamp welding cable and welding machine in good safe operating condition Replace damaged insulation 3 g Never dip the electrode in water for co...

Page 4: ...vent the welding sparks from starting a fire Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas Avoid welding near hydraulic...

Page 5: ...i s et non inflamma bles 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pant...

Page 6: ...e information must be followed to avoid minor personal injury or damage to this equipment CAUTION Please Examine Carton and Equipment For Damage Immediately When this equipment is shipped title passes...

Page 7: ...Connections B 6 Starting the Machine B 7 Adjusting the Output Voltage using the Digital Meter B 7 Local Remote Switch Operation B 7 Auxiliary Power B 7 Overload Protection B 7 Accessories Section C F...

Page 8: ...60 Duty Cycle 33 100 Duty Cycle 66 33 60 Duty Cycle 68 34 Amps 400 300 400 300 Normal Open Circuit Voltage 10 43 MAX OCV 50 Input kVA NEMA 60 Load 23 6 IEC 60 Load 23 2 NEMA 100 Load 22 9 IEC 100 Loa...

Page 9: ...s provided for this purpose See the National Electrical Code for details on proper grounding methods Fuse the input circuit with the recommended super lag fuses Choose an input and grounding wire size...

Page 10: ...the wire feeder receptacle on the CV 400 I c See OUTPUT CONNECTIONS for connection of work and electrode cables Connection of Remote Control K857 NOTE The K864 Remote Control Adapter is required to in...

Page 11: ...iversal Adapter This adapter plugs into the receptacle and provides the user with short wire leads for connections Refer to the instructions provided with the K867 as well as the wiring diagram for th...

Page 12: ...f fumes Use ventilation or exhaust to remove fumes from breathing zone WELDING SPARKS can cause fire or explosion Keep flammable material away Do not weld on containers that have held combustibles ARC...

Page 13: ...tor can choose the optimum output characteristics Solid State Output Contactor no noise no moving parts to wear Digital Voltmeter Ammeter is standard Power on off switch 42 VAC 10 amp auxiliary power...

Page 14: ...ize this effect F 42 VOLT CIRCUIT BREAKER Protects the 42 volt 41 42 circuit in the wire feeder receptacle from overloads and shorts If this circuit breaker opens the CV 400 I will work normally Howev...

Page 15: ...switch to This switch has no effect on the welding polarity In fact if the wire feeder being used does not have a voltmeter the setting of this switch has no effect CV 400 I GRAPHIC SYMBOLS THAT APPE...

Page 16: ...ielding gas C HIGH INDUCTANCE NEGATIVE OUTPUT CONNECTION The high inductance connection is more suit able for short arc welding heavier weldments or when using 75 Argon 25 CO2 shield ing gas This conn...

Page 17: ...ther equipment B CIRCUIT BREAKER Protects the 220 volt auxiliary circuit from over loads and shorts If this breaker opens the CV 400 I will work normally however equipment pow ered by the 220 volt rec...

Page 18: ...e the Local Remote switch see Figure B 1 in the Remote position The remote control now con trols the output voltage in the manner described above This control may be adjusted while welding to change t...

Page 19: ...hat can accommodate either one or two gas bottles or one gas bottle and a Magnum water cooler The CV 400 I lifting eye is not functional when the K874 undercarriage is installed WIRE FEEDER SWIVEL MOU...

Page 20: ...the machine is overloaded the thermostat will open thermal pro tection indicator light will turn on and the output will be zero The fan will continue to run and auxiliary power will still be available...

Page 21: ...n be conducted with out removing the case wrap around cover Step 3 PERFORM COMPONENT TESTS If you have exhausted all of the recom mended tests in Step 2 Consult your Local Authorized Field Service Fac...

Page 22: ...nded wfs voltage settings and angle of approach of wire to work b If problem still persists call Local Lincoln Authorized Field Service Facility Allow machine to cool Be sure to provide adequate venti...

Page 23: ...between 2 4 in wire feeder receptacle 6 If welding with 1 16 aluminum wire and machine is flashing E00 1 Voltage Control misconnected 1 Open in feedback circuitry 2 Faulty PC Board 3 Voltage Adjust p...

Page 24: ...rrect 1 Thermostat circuit has opened 2 Faulty Control PC Board 1 Faulty Control PC Board 2 Voltage Adjust potentiometer defective 3 Voltage Adjust potentiometer leads open 1 Defective power switch 1...

Page 25: ...is in the Remote position 2 Faulty Voltage Adjust potentiometer 3 Leads or connections open in control circuit 4 Malfunctioning Remote Control 5 Faulty Control PC board 1 Poor work connection 2 Improp...

Page 26: ...on the machine 1 Local Remote switch in wrong position 2 Faulty Local Remote switch 3 Faulty Remote Control poten tiometer 4 Leads or connections open in control circuit 5 Faulty Control PC board 1 L...

Page 27: ...alling a replacement PC board If there is damage to the PC board or if replacing PC board corrects problem return it to the local Lincoln Electric Field Service Shop ELECTRIC SHOCK can kill Have a qua...

Page 28: ...then ON to return the machine to normal output CHECKING SNUBBER CIRCUIT In case of an SCR malfunction or failure the snubber assembly should be checked Disconnect the input power to the CV 400 I at th...

Page 29: ...HINES ONLY N B THIS PERMANENT CONNECTION IS MADE AT THE MAIN TRANSFORMER FOR 415V 200 400V AND 380 500V MACHINES ONLY W U L1 L3 1 3 3 9 6 F 12 1 7 4 D 10 10 8 6 10 9 202 200 203 201 s 50 s 58V 58V O2...

Page 30: ...B 214B s s 42A 42 41 42 I K C1 C4 31 000 MFD EACH MAIN TRANSFORMER C 2 41A 41 CIRCUIT BREAKER 220V 52A 2A 52 51 2 L2 INPUT SUPPLY LINES S1 LINE SWITCH RECONNECT PANEL 11 8 5 2 TO A SYSTEM GROUND PER N...

Page 31: ...ILL N A WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION N B DIAGRAM SHOWS ELECTRODE POSITIVE TO CHANGE POLARITY TURN POWER OFF ELECTRODE CABLE 14 PIN AMPHENOL POWER SOURCE CV CV...

Page 32: ...IC SHOCK CAN KILL 6 18 93 NOT USED ON CV CV I POWER SOURCES 42 VAC 115 VAC N E POWER SOURCE FRAME CONNECTION WIRE FEEDER VOLTMETER CONNECTION CONNECTS TO WORK TERMINAL OF POWER SOURCE CONNECT TOGETHER...

Page 33: ...ERSAL ADAPTER PLUG 75 76 77 GREEN N D Only qualified persons should install use or service this machine using the disconnect switch at the fuse box WARNING Turn off input power to the Welding Power So...

Page 34: ...L POWER SOURCE CV CV I OPTIONAL K857 TO WORK LN 25 WIRE FEEDER REMOTE CONTROL OPTIONAL K484 JUMPER PLUG REVERSE ELECTRODE AND WORK CABLES AT POWER SOURCE N C USE OF THE K857 REMOTE CONTROL REQUIRES IN...

Page 35: ...NOL POWER SOURCE CV CV I TO WORK LN 25 WIRE FEEDER OPTIONAL K484 JUMPER PLUG OPTIONAL K864 REMOTE CONTROL ADAPTER WITH K444 1 OPTION N D N D N C N C CONNECT THE K484 JUMPER PLUG TO THE 14 PIN RECEPTAC...

Page 36: ...PUT CONTROL OUTPUT CONTROL OUTPUT CONTROL TRIGGER CIRCUIT TRIGGER CIRCUIT SEE APPROPRIATE WIRING DIAGRAM FUNCTION FUNCTIONS ARE LISTED FOR REFERENCE ONLY AND EACH MAY OR MAY NOT BE PRESENT IN YOUR EQU...

Page 37: ...REAR VIEW 14 PIN BOX RECEPTACLE REAR VIEW AND 14 PIN CABLE PLUG FRONT VIEW K 42 A 32 B GND C 2 L 82 D 4 E 77 M 81 F 76 G 75 N SPARE H 21 I 41 J 31 K 42 J 31 I 41 H 21 N SPARE G 75 F 76 M 81 E 77 D 4...

Page 38: ...OT IS MARKED FOR THE APPROPRIATE CABLE SIZE PER TABLE BELOW AND SKIN CABLE JACKET TO LENGTH SPECIFIED 1 INCH 25 4mm 35 50 2 mm 35 50 2 1 TWIST MATE WELDING CABLE PLUG INSTALLATION INSTRUCTIONS 9 20 91...

Page 39: ...F 11 DIAGRAMS F 11 CV 400 I CONNECTION OF NON LINCOLN WIRE FEEDERS...

Page 40: ...FOR MOUNTING WELDER DOWN USING 5 16 SCREWS 1 68 N B N B HANDLE CONFIGURATION ON EARLIER MODELS 20 05 509 19 65 499 19 20 487 41 58 1056 26 00 660 3 61 91 12 60 320 42 7 11 99 304 3 90 99 28 7 0 1 00...

Page 41: ...6 383 2259 and ask for the Welding School Registrar Lincoln Welding School BASIC COURSE 700 00 5 weeks of fundamentals There is a 10 discount on all orders of 50 00 or more for shipment at one time to...

Page 42: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Page 43: ...e Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci...

Page 44: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...

Reviews: