B-8
INSTALLATION
FLEXTEC™ 500
Paralleling Machines
The Flextec™ 500 power sources may be paralleled for increased
output requirements. No kit is required for paralleling of Flextec™
500 power sources. The Flextec™ 500 can only be paralleled for
constant current processes. Connect the power sources as shown on
Figure B2,
and set the output control of each power sources to one
half of the desired arc current.
WORK PIECE
FLEXTEC 500
MACHINE #1
FLEXTEC 500
MACHINE #2
STICK ELECTRODE HOLDER
ARC GOUGING TORCH
ETC.
TO (-) NEGATIVE STUD
MACHINE #1
TO (-) NEGATIVE STUD
MACHINE #2
TO (+) POSITIVE STUD
MACHINE #2
TO (+) POSITIVE STUD
MACHINE #1
WORK CLAMP
PARALLEL MACHINES
SETUP WITH
FLEXTEC 500
Figure B.2