Lincoln Electric COOL ARC 25 Operator'S Manual Download Page 11

English 9 English 

PERIODIC MAINTENANCE (NOT LESS THAN ONCE 
A YEAR) 

Perform the routine maintenance and, in addition: 

  Keep the machine clean. Using a dry (and low 

pressure) airflow, remove the dust from the external 
case and from the heat exchanger inside. 

  In dirty or dusty environments or if biological growth 

occurs in the coolant, it may be necessary to flush the 
coolant reservoir. Drain the old coolant, rinse the inside 
of the reservoir and circulate rinsing solution through the 
coolant system. Add new coolant when cleaning is 
finished. 

 

 WARNING

 

Hot coolant can burn skin. Always be sure coolant is NOT 
HOT before servicing the cooler. 
 

 WARNING

 

 

Special precautions have to be taken when 
the coolant is removed from the cooler 
reservoir. The coolant must not be poured out 
into ground water, sewerage, or soil. Read 
"Material Safety Data Sheet" (coolant used) 
and contact the local Department of 
Environmental Protection office to obtain 
information on recycling coolant. 

 
The frequency of the maintenance operations may vary 
in accordance with the working environment where the 
machine is placed. 
 

 WARNING

 

Do not touch electrically live parts. 
 

 WARNING

 

Before the case of machine will be removed, the machine 
has to be turned off and the power lead has to be 
disconnected from mains socket. 
 

 WARNING

 

Mains supply network must be disconnected from the 
machine before each maintenance and service. After 
each repair, perform proper tests to ensure safety. 
 

Customer Assistance Policy 

The business of The Lincoln Electric Company is 
manufacturing and selling high quality welding 
equipment, consumables, and cutting equipment. Our 
challenge is to meet the needs of our customers and to 
exceed their expectations. On occasion, purchasers may 
ask Lincoln Electric for advice or information about their 
use of our products. We respond to our customers 
based on the best information in our possession at that 
time. Lincoln Electric is not in a position to warrant or 
guarantee such advice, and assumes no liability, with 
respect to such information or advice. We expressly 
disclaim any warranty of any kind, including any 
warranty of fitness for any customer’s particular purpose, 
with respect to such information or advice. As a matter of 
practical consideration, we also cannot assume any 
responsibility for updating or correcting any such 
information or advice once it has been given, nor does 
the provision of information or advice create, expand or 
alter any warranty with respect to the sale of our 
products 
Lincoln Electric is a responsive manufacturer, but the 
selection and use of specific products sold by Lincoln 
Electric is solely within the control of, and remains the 
sole responsibility of the customer. Many variables 
beyond the control of Lincoln Electric affect the results 
obtained in applying these types of fabrication methods 
and service requirements. 
Subject to Change – This information is accurate to the 
best of our knowledge at the time of printing. Please 
refer to www.lincolnelectric.com for any updated 
information. 

 

Summary of Contents for COOL ARC 25

Page 1: ...IM3013 07 2019 REV05 COOL ARC 25 OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu...

Page 2: ...r future reference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where P...

Page 3: ...FREEZCOOL W000010167 Do not use Pre packaged welding industry coolants These coolants may contain oil based substances which attack the plastic components of the cooler Once added to the cooler these...

Page 4: ...and telephone cables that are in or adjacent to the work area and the machine Radio and or television transmitters and receivers Computers or computer controlled equipment Safety and control equipmen...

Page 5: ...or creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker shall consult their physician before operating this equipment CE COMPLIANCE Thi...

Page 6: ...o not cover the machine with paper cloth or rags when switched on Dirt and dust that can be drawn into the machine should be kept to a minimum This machine has a protection rating of IP23 Keep it dry...

Page 7: ...ent every COOL ARC 25 unit is delivered empty with no coolant in the system To fill the unit locate the plastic reservoir fill cap at the front middle of the unit NOTE The unit can be filled only vert...

Page 8: ...e Take INLET hose colored or tagged blue on most hoses and attach it into the coolant OUT line located on the right side of the connector block at the back of the cooler Then take the OUTLET hose colo...

Page 9: ...al shock Never place fingers into openings of cooler Moving parts can injure Unplug the cooler before filling the reservoir Never operate the cooler with the reservoir fill cap off Never operate the c...

Page 10: ...tions modifications or maintenance it is recommended to contact the nearest Technical Service Center or Lincoln Electric Repairs and modifications performed by unauthorized service or personnel will c...

Page 11: ...m proper tests to ensure safety Customer Assistance Policy The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment consumables and cutting equipment Ou...

Page 12: ...ting sharp bends in water lines Repair leak Fill reservoir Replace power switch Internal water leak Hose clamp loose on one of internal hoses Internal hose punctured Heat exchanger leaking Tighten or...

Page 13: ...r is not listed Contact the Lincoln Electric Service Department for any code number not listed Use the illustration of assembly page and the table below to determine where the part is located for your...

Page 14: ...English 12 English Accessories W000010167 FREEZCOOL coolant...

Reviews: