8
Technical Specifications
INPUT
Input Voltage
230 V
±
10%
One Phase
Input Power at Rated Output
5.4 kVA
Frequency
50/60 Hertz (Hz)
RATED OUTPUT AT 40°C
Duty Cycle
(
Based on a 10 min. period
)
35%
60%
100%
Output Current
135A
110A
80A
Output Voltage
25.2 Vdc
24.4 Vdc
23.2 Vdc
OUTPUT RANGE
Welding Current Range for MMMA and TIG
5A – 135A
Maximum Open Circuit Voltage
55 Vdc
RECOMMENDED INPUT CABLE AND FUSE SIZES
Fuse or Circuit Breaker Size
16A Superlag
Input Power Cable
3 Conductor, 1.5mm
2
PHYSICAL DIMENSIONS
Height
200 mm
Width
120 mm
Length
270 mm
Weight
3.4 0.2 Kg
Operating Temperature
-10°C to +40°C
Storage Temperature
-25°C to +55°C
For any maintenance or repair operations it is recommended to contact the nearest technical service center or Lincoln
Electric. Maintenance or repairs performed by unauthorized service centers or personnel will null and void the
manufacturers warranty.