E-4
TROUBLESHOOTING
AIR VANTAGE
®
600X
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Lincoln Authorized Service Facility for technical troubleshooting assistance before you proceed.
WWW.LINCOLNELECTRIC.COM/LOCATOR
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
Engine goes to low idle but does
not stay at low idle.
No welding output or auxiliary out-
put.
Welder has some/ no output and no
control. Auxiliary output OK
No welding output. Auxiliary output
OK.
No auxiliary power.
1. Faulty Weld Control PCB or Idler
relay.
1. Broken lead in rotor circuit.
3. Faulty Weld Control PCB.
4. Faulty rotor.
1. Faulty remote kit.
2. Faulty output control poten-
tiometer.
3. Faulty output control wiring.
4. Faulty Weld Control PCB,
Idler/Engine Protection PCB or
Chopper PCB.
1. WELDING TERMINALS switch in
wrong position, be sure switch is
in WELDING TERMINALS
ALWAYS ON position.
2. Faulty Weld Control PCB,
Idler/Engine Protection PCB or
Chopper PCB.
1. Open breakers may need to be
reset.
2. Faulty receptacle.
3. Faulty auxiliary circuit wiring.
4. RCD tripped.
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.
FUNCTION PROBLEMS
Observe all Safety Guidelines detailed throughout this manual