SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
Frequent relief valve
operation
Pressure control line
plugged or frozen
Remove and clear the line
System still at high
pressure
Wait for system blow-down or
bleed off all system pressure
Defective relief valve
Replace the valve
Compressor does not
run
High system pressure
Clutch will not engage with
more than 2 psi system
pressure
High oil temperature
See “frequent over-
temperature shut-
down”
Frequent over-
temperature shut-down
Low oil level
Check oil level with
equipment on level ground
Restricted oil lines
Check for kinked or pinched
lines
Plugged oil filter
Replace oil filter
Cooler not functioning
or plugged
Replace or clean oil cooler
Engine cooling
system failure (high
engine temperature)
Correct problem
High ambient
temperatures
Reduce duty cycle
Oil temperature
sensor failure
Replace if defective
Requires service
Perform 500hr (6 month)
service
Excessive oil in the air
Coalescing separator
failure
Replace element
Clogged scavenge
line screen
Clean or replace
High oil level
Check oil level with
equipment on level ground
Operating angle in
excess of 25 degrees
from horizontal
Reduce operating angle
Air operated
equipment is faulty, or
not correctly
connected to supply
valve. Discharge
pressure too low.
Test air operated equipment
for proper operation and
connect to supply valve
Using incorrect oil
Drain incorrect oil from all
components. Flush and
replace with VMAC certified
oil
Incorrect start-up/
shutdown procedures
Observe start up/ shutdown
procedures detailed in this
manual.
Objectionable noise
level
Excessive gear wear
Replace air compressor