The Flextec™ 500 P welding modes utilize the UltimArc
TM
Arc Control
Feature for adjusting the focus or shape of the arc. UltimArc
TM
Control
is adjustable from -10.0 to +10.0 with a nominal setting of 0.0.
(See Figure C.3)
Increasing the UltimArc
TM
Control increases the pulse
frequency and background current while decreasing the peak current.
This results in a tight, stiff arc used for high speed sheet metal
welding. Decreasing the UltimArc
TM
Control decreases the pulse
frequency and background current while increasing the peak current.
This results in a soft arc good for out of position welding.
The UltimArc
TM
Arc Control can be accessed through the ArcLink
compatible wire feeder user interface.
For additional information about UltimArc
TM
Arc Controls and pulse
welding procedure Lincoln Electric publishes process documents as
informational guides on various welding procedures. Access to the
process documents can be attained at the following web address:
http://www.lincolnelectric.com/en-us/equipment/advanced-process-
welders/Pages/power-wave-resources.aspx
FLEXTEC™ 500 P
Arc Control OFF
Medium Frequency and Width
Arc C10.0
High Frequency, Focused
Arc Control -10.0
Low Frequency, Wide