background image

LEDs MEANING

White breath

BUS acquisito / stand-by

Blue yellow-red-green sequence

(Supercar)

BUS not connected

White-red flashing

Keyreader tamper opened

White flashing

BUS anomaly - acquire BUS on the 

board

LED yellow-red-green

fixed on

Confirmation of the complete 

key memorization

ELECTRICAL CONNECTIONS AND CONNECTION EXAMPLE

In order to make the electrical connections conveniently and easily, connect the power supply, ground and 

data between the keyreader board and the interface board, respecting the silk-screen printed on both boards. 

Then connect the input / output terminals to the relevant external devices.

NOTE:

Connect the mass of the keyreaders to the only mass on the interface board

KEYS STORING

To store the keys, follow the steps reported below
• 

Press and release the programming button; the red LED on the 

board flashes slowly (timeout of 1 minute) and the LEDs of any 

connected readers is switched off.

• 

Insert the key to be stored in any keyreader connected to the 

BUS.

• 

A short flash is obtained if the key is not yet stored; you get a 

flash of permanent rejection (until the key remains inserted) if 

already stored

• 

Extract the stored key.

• 

Repeat the sequence for all the keys (max 40)

• 

To  exit  programming  without  waiting  for  the  timeout,  briefly 

press the programming key.

INITIAL RESET 

Proceed as described below:

• 

With the board disconnected, press and hold the programming key 

B

.

• 

Power up the card while continuing to hold down the programming button 

B

 for at least 3 seconds, then release the button.

NOTE:

All the codes on the card will be deleted as well as all the peripherals previously memorized on the BUS line;

BUS STORAGE 

To carry out the acquisition on the BUS it will be sufficient power supply the board that within 30’’ will automatically configure the map of 

keyreaders. For all 30 ‘’, necessary, you will have the rapid flashing of the red LED.

NOTE:

• 

To add, remove and / or replace the keyreader, switch off the board and switch it on again. At the end of the operations, the new BUS 

mapping will be performed.

• 

The maximum number of connectable keyreaders is defined by the current available from the control unit or remote power supply to 

which the S 137 PLUS board is connected (each inserter absorbs an average of 34 mA).

Fig. 6 

Fig. 7 

NC   C   NA  LM +OFF BUS +   D         +12

 

1  2  

 4 

ON 

Mode relay exchange

Impulsive or step by step

jumper function

LM:

 Input

 

+OFF:

 Input

BUS: 

 electrical output

10÷15 Vdc power supply

Ground (common)

ARMING

• 

Insert the key and press it towards the key reader until it clicks, only 

the red LED will light up;

• 

then extract the key.

DISARMING

• 

Insert the key and press it towards the key reader until it clicks, only 

the red LED will go out;

• 

then extract the key.

Fig. 8 

1  kOhm  resistor  (supplied,  colors  brown, 

black, red) for the management of the + OFF 

input

Summary of Contents for 4037S137PLUS

Page 1: ...C NA Uscita relè mono bistabile Fig 1 DESCRIZIONE DELLE PARTI DELLA SCHEDA PARTE DESCRIZIONE A LED di visualizzazione B Tasto di programmazione C Dip switch per le impostazioni D Relè E Morsettiera C A B E D IMPOSTAZIONE DEI DIPSWITCH n DECRIZIONE OFF ON 1 Uscita BUS Massa normalmente presente morsetto aperto quando si attiva l uscita Morsetto normalmente aperto commuta a massa quando si attiva l ...

Page 2: ...l tasto di programmazione RESET INIZIALE Procedere come descritto di seguito A scheda disalimentata premere e mantenere premuto il tasto di programmazione B Alimentare la scheda continuando a tenere premuto il tasto di programmazione B per almeno 3 secondi quindi rilasciare il tasto NOTE Tutti i codici presenti sulla scheda saranno cancellati così come tutte le periferiche precedentemente memorizz...

Page 3: ...utput Fig 5 BOARD PART DESCRIPTION PART DESCRIPTION A Visualization LED B Programming switch C Dip switches for settings D Relè E Terminal block C A B E D Manuale di installazione ed uso MADE IN ITALY The CE declaration of this item is available on www lince net website Via Variante di Cancelliera snc 00072 ARICCIA Roma Tel 39 06 9301801 Fax 39 06 930180232 info lince net www lince net ART 4037S13...

Page 4: ...NITIAL RESET Proceed as described below With the board disconnected press and hold the programming key B Power up the card while continuing to hold down the programming button B for at least 3 seconds then release the button NOTE All the codes on the card will be deleted as well as all the peripherals previously memorized on the BUS line BUS STORAGE To carry out the acquisition on the BUS it will ...