Lincat WMB5FX Installation, Operating And Servicing Instructions Download Page 6

IS 745   ECN 4386 

Page 6 of 12 

 

 

4

6

4

353

218

A

DISPLAY

B

DISPENSE BUTTON

C

OVERFLO W RESET

D

WATER FILTER

E

DRAIN VALVE

F

CONDENSATE/O VERFLO W

G

WATER INLET CONNEC TION

H

ELECTRICAL CO NNECT ION

29

50

5

4

2

8

1

5

2

49

74

D

E

9

6

F

G

H

A

B

C

37

OPERATING INSTRUCTIONS

 

 
Only qualified or trained personnel should use this appliance. 

 

First Use 

 
Switch on both mains water and electricity supplies and leave the boiler for 13 mins 
to fill completely. Unit will display 

READY

 when set temperature is reached. 

 
New filters have a small amount of loose, harmless, carbon particles. Drain off 
approximately 3 litres of water when first setting up or replacing filter.  

 

Regular operation

 

 
The appliance starts automatically shortly after the electrical supply is turned on, 
filling with water and heating.   
The unit will display ‘

WAIT

’ whilst it fills and heats. It will display ‘

READY

' when 

water can be drawn off. 
 
To ensure that water is always hot, only small quantities are added constantly 
during the heating cycle. The appliance is designed to be left on permanently, only 
to be turned off for descaling or maintenance. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Fig. 2 

 
 

Summary of Contents for WMB5FX

Page 1: ...ater Boiler Glass Front WMBFX B Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number _______________...

Page 2: ...tion and Guarantee 10 11 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and no...

Page 3: ...et is accessible at all times Strip plastic coating and clean the appliance before use During operation parts may become hot avoid accidental contact Disconnect this appliance before servicing mainten...

Page 4: ...lated sleeving having a temperature rating of at least 60 C Supply cords shall be oil resistant sheathed flexible cable not lighter than ordinary polychloroprene or equivalent elastomer sheathed cord...

Page 5: ...Ratings Model kW Amps WMB5FX 3 0 13 0 Water Installation Connect the supplied white water inlet hose to the inlet connection point on the base of the boiler and the other end to the mains supply via a...

Page 6: ...splay READY when set temperature is reached New filters have a small amount of loose harmless carbon particles Drain off approximately 3 litres of water when first setting up or replacing filter Regul...

Page 7: ...fe after replacement H Water in Adjustment Clock At any point press the WAIT or READY on the display Now press Settings Then press Clock followed by Set Time Now press day followed by arrow keys to se...

Page 8: ...main display Filter replacement The filter display shows the estimated life left in the filter cartridge A reminder message is displayed when the filter needs changing Fig 4 To replace the filter From...

Page 9: ...olate the boiler from the electrical supply Turn off the power and allow the water to cool to 60 C Remove the outer surround secured by 3 screws Remove the top cover secured by 5 screws Remove the ins...

Page 10: ...erial plate for the model and serial number as this will help us quickly identify the part you require Part Number Description Used on DV02 Drain valve EL277 Element FC04 Water filter FH04 Filter head...

Page 11: ...nd does not diminish your statutory or legal rights The guarantee does not cover Accidental damage misuse or use not in accordance with the manufacturer s instructions Scale related issues Consumable...

Page 12: ...IS 745 ECN 4386 Page 12 of 12...

Reviews: