IS205 ECN3592
7
A
B
C
D
SERVICING
SERVICE ACCESS
To access and service the gas control valves
Remove the control knobs and fascia panel to gain access to the valves.
Remove the two screws securing the valve boss and carefully withdraw the spindle
from the valve.
Grease as necessary and refit parts. Carry out gas soundness check.
FASCIA PANEL REMOVAL
Remove the debris drawer (A) and fat tray (B).
Remove the control knobs (C).
Remove the screws left and right on the
underside of the fascia panel (D). Tilt the fascia
panel from the bottom up and lift clear of the
hob top.
OPERATIONAL CHECK
Commissioning must include an operational check of all controls.
Check that each burner can be lit at both full rate and low rate.
Check that each burner will remain lit when turned to low rate.