Means of isolation with at least 3mm contact separation in all poles must be
incorporated into the fixed wiring of this appliance.
The fixed wiring insulation must be protected by insulated sleeving having a
temperature rating of 60 Deg C.
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
If this appliance is fitted with castors, use caution at all times when manipulating or
moving, and lock castors when appliance is in position.
Connection to the electrical supply is made at the rear of the appliance. Remove
the protective cover and fit a suitable cable to the strain relief. Connect to the inlet
terminal block. This appliance is supplied for connection to a three phase supply.