SERVICING, MAINTENANCE AND 
COMPONENT REPLACEMENT

 

 
 

Door inner glass: Slide glass up to clear side brackets and remove from top.  To 
replace the glass, reverse the procedure. 

 

Light bulb: Lever off the glass cover using a small flat bladed screwdriver.  Unscrew 
bulb.  To replace the bulb, reverse the procedure. 

 

Door seals: These simply hook out of the holes.  Hook out to remove and replace by 
hooking the new seal into position. 

 

All other servicing, maintenance and component replacement on this appliance 
should be carried out by one of our recommended service engineers. 

 
 

 

 

Please refer to the Service Help Desk number on the final page of this manual. 

 

 

Part Number 

Description 

BU55 

Door hinge bush 

EL232 

Element 

FA106/S 

Fan  

FE37 

Foot LCOT, LCOS 

FE10 

LCOXL 

GA75 

Fan gasket 

GL707 

Door inner glass LCOT 

GL709 

Door inner glass LCOS 

GL711 

Door inner glass LCOXL 

KN250 

Control/Timer knob 

LA14 

Lamp 

LE14 

Clear cover for On/Off switch 

NE42 

Amber neon 

PL202 

Mains cable 

SE35 

Door seal top 

– LCOT or Door seal side LCOXL 

SE94 

Door seal side 

– LCOT, LCOS 

SE95 

Door seal top - LCOS 

SE96 

Door seal top - LCOXL 

SH139 

Shelf LCOT 

 SH140 

 Shelf LCOS 

SH141 

Shelf LCOXL 

SW69 

Switch 

TH46 

Control thermostat 

FAULT FINDING

 

SPARE PARTS LIST

 

Summary of Contents for Lynx 400

Page 1: ...onvection Ovens LCOT LCOS LCOXL Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number _______________...

Page 2: ...Guarantee 8 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and notices Ensure...

Page 3: ...an the appliance before use During operation parts may become hot avoid accidental contact Disconnect this appliance before servicing maintenance or cleaning TECHNICAL DATA Model Height mm Width mm De...

Page 4: ...olychloroprene or equivalent elastomer sheathed cord code 60245 IEC 57 Install this appliance on a level surface ensuring all vents are unobstructed Install this appliance on a level surface ensuring...

Page 5: ...lluminates and extinguishes when temperature is reached During operation the amber neon will periodically illuminate as the element cycles Adjacent to the temperature control is a 55 minute mechanical...

Page 6: ...in the oven may be removed to allow a thorough clean of the interior The shelves are bolted in place tightly during transport to avoid damage On delivery back off the 3 bolts holding each shelf by 2mm...

Page 7: ...ppliance should be carried out by one of our recommended service engineers Please refer to the Service Help Desk number on the final page of this manual Part Number Description BU55 Door hinge bush EL...

Page 8: ...mprehensive UK mainland 2 year warranty The guarantee is in addition to and does not diminish your statutory or legal rights The guarantee does not cover Accidental damage misuse or use not in accorda...

Page 9: ...IS 733 ECN 4552 Page 9 of 9 minutes due to administrative requirements such as on health and safety risk assessments will be chargeable at the prevailing rate...

Reviews: