Lincat LSF Installation And User Instructions Manual Download Page 5

IS312  ECN3016            

Page 5 

SERVICE INFORMATION 

GUARANTEE 

CLEANING AND MAINTENANCE 

 

 

 

 

CLEANING 

 

Disconnect the unit from the electricity supply and ensure it is cool to touch before starting any 

maintenance or cleaning. Use a mild detergent in hot water and a soft cloth. Do not use abrasive creams 

or scourers. 

 

Remove basket and batter plate, and slide control head up and lift off.  Remove tank and pour away oil. 

 

Wipe the control head clean with a damp cloth – 

do not allow water to penetrate control head. 

 

After cleaning, ensure tank is thoroughly dry.. 

 

MAINTENANCE 

 

Regular cleaning of the unit is recommended.  

 

No regular maintenance is required. 

 

 

 

 

 

 

 

 

 

For help with the installation, maintenance and use of your Lincat equipment, please contact our service department: 

 

01522 875520 

 

All service work, other than routine cleaning should be carried out by one of our authorised service agents. We 

cannot accept responsibility for work carried out by other persons. 

 

To ensure your service enquiry is handled as efficiently as possible, you need to have the following details available: 

 

 

Brief details of problem 

 

Product code, type number and serial number of unit (both on serial plate) 

 

Lincat reserve the right to carry out any work under warranty during normal working hours, ie Monday to Friday, 

08:30 a.m. – 17:30 p.m. 

 

 

 

 

 

 

 

 

This unit carries a comprehensive UK twelve-month warranty. The guarantee is in addition to, and does not 

diminish your statutory or legal rights. 

 

The guarantee does not cover

 

 

Accidental damage, misuse (or use not in accordance with the instructions in this User Guide), or 

consumable items. 

 

Damage due to incorrect installation, modification or unauthorised service work. 

 

The manufacturer disclaims any liability for incidental, or consequential damages. 

Summary of Contents for LSF

Page 1: ... Guide your Lincat product will give years of trouble free use IMPORTANT INFORMATION Please read all of the safety and operating instructions carefully before using this product Please pay particular attention to all sections of this User Guide that carry warning symbols and notices WARNING This is a Warning symbol This symbol is used throughout the user guide whenever there is a risk of personal ...

Page 2: ... it should be replaced by Lincat Ltd or other suitably qualified persons in order to avoid a hazard Do not try to move this unit when the tank contains oil Disconnect the unit from the electric supply before servicing This unit must be earthed Electric fryer with cable and 13 Amp plug Rubber feet x 4 User Guide Guarantee Card Batter Plate Dust Cover Lid Specific Accessories Unit Code LSF Basket BA...

Page 3: ...wire to L Live 4 3 6 2 5 7 1 Fig 1 Model LDF 1 Batter Plate 2 Oil Markers Max Min 3 Green Neon 4 Amber Neon 5 Control Head 6 Control Knob 7 Basket Support Fig 1 also represents the other fryer models in the Lynx 400 range Before first use Disconnect the unit from the power supply Remove the batter plate lift the control head out of the rear channel Fig 2 and clean the tank with a little hot water ...

Page 4: ... allow the oil to drain Safety High Limit Thermostat Lincat electric fryers are fitted with two thermostats One controls the temperature of the oil the other prevents the oil temperature from reaching a dangerous level if there is a fault with the unit or power supply Ensure that these thermostats are not damaged during use and cleaning If the green neon lights up but the element does not heat up ...

Page 5: ...rvice work other than routine cleaning should be carried out by one of our authorised service agents We cannot accept responsibility for work carried out by other persons To ensure your service enquiry is handled as efficiently as possible you need to have the following details available Brief details of problem Product code type number and serial number of unit both on serial plate Lincat reserve...

Page 6: ...IS312 ECN3016 Page 6 THIS PAGE LEFT INTENTIONALLY BLANK ...

Page 7: ...IS312 ECN3016 Page 7 THIS PAGE LEFT INTENTIONALLY BLANK ...

Page 8: ...IS312 ECN3016 Page 8 THIS PAGE LEFT INTENTIONALLY BLANK ...

Reviews: