SECURITY DISTANCES
•
From NOT combustible object :
−
A > 500 mm
B > 200 mm
C > 200 mm D > 1500 mm
•
From combustible object and from principal wall in rein forced concrete :
−
A > 1000 mm
B > 400 mm
C > 400 mm D > 1500 mm
•
The minimal distance between the stove and every flammable object around it is 1.5
meter.
1.4
Connection
•
Before connection check technical data reported in the technical plate ( Chap. 4 ) and
control that it correspond to the ones required in the order.
•
All heating biomass equipment especially wood stove has to evacuate the combustion
products in a flue built in conformity with normative in force.
•
The following instructions describes „ informations for a good installation „ and it refers
to a normative in force but it are not to be consider exhaustive for installations laws.
Valid for all the Models
To measure from apparatus
external surface for every models
Mod 480AZ-490AZ
Mod 470AZ