PIEZO™

The PIEZO-electric sensor is an electronic sensor integrated in the column, which reacts on load changes. If the desk drives 
into an obstacle, the load changes. This load change is picked up by the PIEZO-electric sensor and the signal is sent to the 
control box.
For optimised safety against squeezing and blocking on a desk, LINAK has developed a DL19 columns with integrated sensor, 
called PIEZO. The option minimises the risk for damages on a desk caused by squeezing or blocking of obstacles in up and 
down direction. Examples could be driving down into an office chair or into a container or up into a windowsill. To a certain 
extent, the system also increases the personal safety, but it does not comply with legislation describing personal safety.
PIEZO allows the DL19 columns to have the standard built-in dimension and the standard stroke length. There are no visible 
changes to the column.

The Desk Sensor™ 1 (DS1) is a small, compact adapter to be plugged into the control box or, in IC systems, into the master 
column. The DS1 is based on gyroscope-technology, and it detects even little tilting of the desk when the desk is driving up or 
down. Upon detected tilting, the system stops and drives in the opposite direction to avoid collision and damage to the desk 
or the object. The DS1 can detect both hard and soft obstacles, and it works with both 2-part and 3-part columns. 
Optionally, the DS1 can also be combined with the well-known PIEZO™ technology ensuring an even higher level of anti-
collision.

Do not use the DL19 with PIEZO in combination with a crossbar or a foot construction where you place the column in 
a tube welded on the foot.

Summary of Contents for DESKLINE DL18

Page 1: ...Page 1 of 35 LINAK COM DESKLINE DL18 DL19 with CBD6S User manual...

Page 2: ...INE DL18 DL19 system 11 Warranty 11 Maintenance 11 Service of double insulated products 12 ETL markering 13 Description of the DESKLINE DL18 DL19 system 14 Installation 15 Mounting the motor housing 1...

Page 3: ...ality testing Should you nevertheless experience problems with your LINAK product system you are always welcome to contact your local contact LINAK subsidiaries and some distributors situated all over...

Page 4: ...s 1 single DL18 DL19 DL19 PLUSTM DL19 PLUS High speed or 2 in parallel Control boxes CBD6S 200 W CBD6S 300 W Controls DPF1M DPG1M DPG1B if memory function is required DP1CS DPT DPF1C DPG1C if memory f...

Page 5: ...NOTE symbol may result in serious damage to the system or one of its components It is important for everyone who is to connect install or use the systems to have the necessary information and access...

Page 6: ...dual parts must be connected before connecting the control box to the mains See the User Manual for LINAK actuators if necessary During operation If the control box makes unusual noise or smells switc...

Page 7: ...ce or knowledge of the product products must not use the product products Besides persons with reduced physical sensory or mental abilities must not use the product products unless they are under surv...

Page 8: ...pecial gaskets must be fitted Products under warranty must also be returned to authorised LINAK service centres Further information on DESKLINE warranty can be found on the LINAK website www linak com...

Page 9: ...a0b00470645 where a can be 0 or R b can be A B C or D DL2 DL2abCcdefffggg where a can be 3 6 or 7 b can be from 0 to 3 c can be A or B d can be 0 F or G e can be from 0 to 7 fff can be from 300 to 500...

Page 10: ...n be from 300 to 500 ggg can be from 445 to 655 BASELIFT BASE1000A0F100100 Desk Panel s DPA DPB DPH DPF1K DPF1M DPF2K DPF3K DPF1C DPF1D DPF1U DPF1W DPF4T DPG1K DPG1M DPG1B DPG1C DPT DP1V01 DP1CS DP1K...

Page 11: ...nd plugs and check for correct functioning as well as fixing points Cleaning the desk panel Clean your desk panel with a soft damp cloth Universal cleaning detergents may be used For disinfection of t...

Page 12: ...usually achieved at least in part by having two layers of insulating material surrounding live parts or by using reinforced insulation There is no earthing grounding means provided on the product and...

Page 13: ...CSA Std C22 2 No 68 09 ETL Recognized Component mark for Canada and United States C N 4009507 Conforms to UL962 Cert to CSA Std C22 2 No 68 09 ETL Recognized Component mark for Canada and United Stat...

Page 14: ...minutes pause stated in the data sheets must NOT be exceeded as this will result in a superheating of the motor the brake and the spindle nut Exceeding the duty cycle will result in a considerable red...

Page 15: ...ax 7 5 Nm Always use six M6 screws for mounting the motor housing on the top frame Mounting screws must not go further than max 10 mm into the motor housing Sufficient stability of the desk is only ob...

Page 16: ...ss Max 16 mm plus foot thickness for M6 Max 14 mm plus foot thickness for M8 2 Fasten screws thoroughly torque max 10 Nm The holes in the foot must be sufficiently larger than 6 8 to ensure space for...

Page 17: ...e sure that you do not pull out the bracket in the column when tightening the screws for the assembly The maximum torque for tightening the 2 x M8 screws in the bracket is 15 Nm To avoid damage of the...

Page 18: ...of a monitor directly above the motor housing may cause malfunction of the monitor Magnets inside the motor may interrupt the picture on the monitor depending on distance and type of monitor If this...

Page 19: ...of 10 mm 8 to 10 mm can be used 5 Fasten the mounting screws max torque 1 Nm Notes If the control box is mounted in a top frame bar with the width of the motor housing it can be mounted with one screw...

Page 20: ...ix the cable to the tabletop using a clip observing the 30 mm minimum bending radius R Connecting the system 1 Connect the first DL DB to socket 1 next to port A2 on the control box using the 6 pin pl...

Page 21: ...mm out again Do not release the down button until the movement has stopped completely If the button is released before the sequence is completed the initialisation is interrupted and must be started...

Page 22: ...otecting the desk from being damaged when driven into such objects This feature is called an anti collision system To a certain extent this feature also increases the personal safety but it does not c...

Page 23: ...with legislation describing personal safety PIEZO allows the DL19 columns to have the standard built in dimension and the standard stroke length There are no visible changes to the column The Desk Se...

Page 24: ...ly and all lifting columns will start to run in the opposite direction approx 50 mm This return drive is done automatically and continues with or without any control key pressed for max 2 5 sec The an...

Page 25: ...ributor or subsidiary Accessories Please contact your nearest LINAK contract distributor or subsidiary Warning By unauthorised opening of the system there is a risk that it may malfunction at a later...

Page 26: ...lmost all our cast plastic parts are supplied with an interior code for plastic type and fibre content if any Main groups of disposal Product main groups Metal Scrap Cable scrap Electronics scrap Plas...

Page 27: ...Page 27 of 35 Label for DL19 800 N Label for CBD6S 200W SMPS Label for CBD6S 300W SMPS up to 4 channels Labels Label for DL19 1200 N 1200 N DL19100B00650560 Label for DL18...

Page 28: ...mm Version Combination code B Built in length mm S Stroke length mm O Outer profile length mm EU DL18xxxxxx500645 645 500 590 DL18 built in length stroke length and outer profile length mm DL18 dimens...

Page 29: ...Page 29 of 35 DL18 Bracket options Combination code Std bracket Bench left Bench right DL18xx1xxxxxxxxx X DL18xxLxxxxxxxxx X DL18xxRxxxxxxxxx X Bracket options dimensions in mm...

Page 30: ...O Outer profile length mm EU DL19xxxxxx650560 560 650 498 DL19 built in length stroke length and outer profile length mm DL19 motor housing and profile dimensions mm DL19 motor housing and profile di...

Page 31: ...Bench left Bench right DL19xx1xPxxxxxxx X DL19xxLxxxxxxxxx X DL19xxRxxxxxxxxx X Bracket options dimensions in mm Only available with PLUSTM columns Bracket options 27 60 60 Created By Mads Boyschau Es...

Page 32: ...of 35 Sockets Profile designs Combination code Type DL18xxxxx0xxxxxx Standard DL19xxxxx0xxxxxx Standard DL19xxxxxExxxxxx Standard Standard Standard PLUS without trim rings PLUS with trim rings Profile...

Page 33: ...Page 33 of 35 CBD6S 200W SMPS CBD6S 300W SMPS up to 4 channels...

Page 34: ...under which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying condit...

Page 35: ...011 4303 8989 8900 Fax 011 4032 0184 www novotecargentina com Colombia MEM Ltda Tel 57 1 334 7666 Fax 57 1 282 1684 www mem net co India Mechatronics Control Equipments India Pvt Ltd Tel 91 44 2855848...

Reviews: