Page 1 of 24
LINAK.COM
/DESKLINE
DESK FRAME 2 (DF2)
User manual
Page 1: ...Page 1 of 24 LINAK COM DESKLINE DESK FRAME 2 DF2 User manual...
Page 2: ...uble insulated products 6 Misc 6 Repairs 6 Only for EU markets 7 Only for Non EU markets 7 Misuse 7 Manufacturer s declaration 8 Declaration of Conformity 9 Misc on the DESKLINE system 10 Warranty 10...
Page 3: ...ctory they undergo full function and quality testing Should you nevertheless experience problems with your LINAK product system you are always welcome to contact your local contact LINAK subsidiaries...
Page 4: ...before cleaning or servicing WARNING To reduce the risk of burns fire electric shock or injury to persons Unplug from outlet before putting on or taking off parts It is important for everyone who is t...
Page 5: ...peration If the control box makes unusual noise or smells switch off the mains voltage immediately The maximum total load on the frame is 160 kg equally loaded i e 80 kg on each column The 160 kg incl...
Page 6: ...st also be returned to authorised LINAK workshops Warning If any of the DESKLINE products are opened there will be a risk of subsequent malfunction Warning The DESKLINE systems do not withstand cuttin...
Page 7: ...involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Only for Non EU markets Persons who do not have the necessary exper...
Page 8: ...achinery Directive 2006 42 EC ANNEX I Essential health and safety requirements relating to the design and construction of machinery 1 5 1 Electricity supply The relevant technical documentation is com...
Page 9: ...DLF Feet models DLFaab11cddd000 aa 06 or 019 b 1 or 2 c A B or D ddd 560 or 710 complies with EMC Directive 2014 30 EU according to following standards EN 61000 6 1 2019 EN 61000 6 3 2007 A1 2011 AC 2...
Page 10: ...nother application they will be covered by 18 months warranty If there is any doubt that returned products are within the warranty period this must be treated as if they are covered by the warranty We...
Page 11: ...talled motor in the beam ensure that only the mains and the desk panel cables are visible The DF2 is of the well known LINAK quality and performance similar to other 3 part columns As standard the DF2...
Page 12: ...onally a mounting kit containing screws for mounting the tabletop and the DPG as well as cable relief clamps The feet 2 pieces including the screws for mounting and the adjustment screws for the foot...
Page 13: ...d by the SW during use and it depends on load run time etc The DF2 duty cycle is 5 1 minute continuous use at full load followed by 19 minutes pause If the DF2 is being used beyond the duty cycle the...
Page 14: ...ustable in 50 mm steps The beam must not be pulled completely apart in order not to pull the drive shaft apart Minimum adjustment in the connection end is 100 mm to keep power and RJ45 sockets accessi...
Page 15: ...f DF2 frame 6 Fasten DF2 frame to tabletop using 20 mounting screws as follows 6 a 8 screws at ends of beam Use one of these to fix mains cable to beam with cable clamp creating a cable relief see ste...
Page 16: ...completely retracted position 7 2 Tilt columns and place correctly on beam using guiding notches 7 3 Fix column to beam by pressing down until a click is heard and both pawls lock column in correct po...
Page 17: ...sk panel to tabletop using mounting screws 8 3 Fasten cable to tabletop using two screws and two cable clamps Ensure that only one desk panel at the time is connected to the DF2 9 Connect power cable...
Page 18: ...he feet always use four M6 or two M8 bolts with the following specifications Quality Min grade 8 8 Length Min 10 mm plus foot thickness max 16 mm plus foot thickness 10 2 Fasten bolts thoroughly torqu...
Page 19: ...screw and remove desk panel 5 Unscrew and remove feet 6 Place disassembly tool on beam with the ridges facing towards the cantilever 7 Press straight down to loosen cantilever and make pawl release co...
Page 20: ...defined as hardware software technical advice etc related to an existing or new customer application LINAK products as defined above are applicable for a wide range of applications within the Medical...
Page 21: ...vided into steel aluminium copper and plastic can be divided into ABS PA PE PP As an example the table below breaks down the different components in LINAK products to various recycling groups By now a...
Page 22: ...ax 1750 50 50 5 50 Min 1018 Max 1618 137 5 15 15 6 329 5 417 4 53 49 Created By Bjarne Skov 2019 03 14 Modified By Bjarne Skov 2020 01 30 SCALE 7 50 Drawing No DF2_BEAM Minimum adjustment is 100 mm to...
Page 23: ...ard A A 225 255 450 510 18 53 5 5 12 4 546 Created By Bjarne Skov 2019 05 14 Modified By Bjarne Skov 2020 01 30 SCALE 3 10 Drawing No DF2_CANTILEVER_1 SECTION A A 1167 4 498 517 3 80 1 0 50 1 0 104 2...
Page 24: ...Page 24 of 24 Desk Frame 2 Column DF2LS06 BIFMA DF2LS19 Standard...
Page 25: ...k co uk Italy LINAK ITALIA S r l Phone 39 02 48 46 33 66 Fax 39 02 48 46 82 52 www linak it Japan LINAK K K Phone 81 45 533 0802 Fax 81 45 533 0803 www linak jp Malaysia LINAK Actuators Sdn Bhd Phone...