Mounting guidelines for the DL11 (foot part)
The DL11 is supplied with 4 M6 and 2 M8 threaded holes for mounting of the foot. We advise you to fasten the foot by means
of 4 pcs. M6 screws or 2 pcs M8 screws of a good quality (min. 8.8) and of a suitable length. The holes in the foot ought to be
sufficiently larger than ø6 so that it is possible to bring the foot to a level line at assembly/mounting.
The 4 M6 holes in the bottom of the column are placed on an Ø46mm pitch circle. The 2 M8 holes have their center 25 mm
from the center of the column.
96.5
177.1
32.53
50
32.53
46
35.4
Bottomplate
2XM8
4XM6
Foot
Mounting of the foot part of standard DL11
M6 screws must not go further than 20mm into the DL11 column. M8 screws must go min. 9 mm and not further than 11 mm
into the column. The thrust moment must not exceed 10Nm in the bottom plate thread.
Mounting of the foot part of standard DL11 with PIEZO™
M6 screws must not go further than 16mm into the DL11 column. M8 screws must go min. 9 mm and not further than 11 mm
into the column. The thrust moment must not exceed 10Nm in the bottom plate thread.