DIP Switch Setting
Fan Power Switch
Alarm Mode Switch
Turn the number 2 switch to ON position to activate the internal fan. This will maintain the
temperature inside and make the electric parts longer life.
Alarm Mode can be set as Lock or Release mode. Turn number 1 switch to ON position to
choose Release mode. Turn number 1 switch to OFF position to choose Lock mode.
Fast Dome has 6 alarm inputs and 1 output, which can be set either NC (normally close) or
NO (normally open) mode. Turn number 2 switch to ON position to choose NC mode.
Turn number 2 switch to OFF position to choose NO mode.
Camera ID Switch
Alarm Mode Switch
Fan Power Switch
FAST DOME CAMERA SET UP
6
RS-485 Protocol Dip Switch