3. INTERCONNECTING DIAGRAM
PAN/TILT OUTPUTS
1
2
6
3
5
4
1
2
3
4
5
6
AUTO
COMMON
DOWN
UP
RIGHT
LEFT
LENS OUTPUTS
1
2
6
3
5
4
1
2
3
4
5
6
GROUNDING
IRIS
NO CONNECTION
ZOOM
FOCUS
NO CONNECTION
4. REMARKS
a. The PIH-308 controls 5 sets of PAN/TILTS which are fed AC input of 117V or 230V
(potion).
4
INPUT
a.c. 117V
or
a.c. 230V
PIH-308
OUTPUT
a.c. 117V OR a.c. 230V (FOR PAN/TILTS)
DC 12V
.................... (FOR LENS)
b. The PIH-308-24 offers a.c. Input of 24V by adding an external power supplier (PS-10).
INPUT
a.c. 117V
or
a.c. 230V
a.c. 24V
Converter
PS-10
OUTPUT
a.c. 24V
PIH-308-24
OUTPUT
DC 12V
(FOR LENSES)
a.c. 24V
(FOR PAN/TILTS)