PAN/TILT UNIT
INSTALLATION
The PIH-302 is intended to be mounted on a PIH-5003 wall Mount. Installation of the pan
and tilt drive to the wall mount requires a stainless steel 1/4-20 screw supplied with the
wall mount. Note the ribs on the underside of the PIH-302 base engage slots in the
PIH-5003. This allows positioning of the PIH-302 in any of four directions with respect to
the wall mount. Secure PIH-302 to the wall mount using screw from underside of wall
mount into PIH-302 and tighten.
WIRING OF UNIT
Fabricate the interconnecting cable in accordance with Figure 1. For proper operation.
Figure 1
PIH-302 Cable Assembly Diagram
1
2
3
4
5
6
AUTO
COMMON
TILT DOWN
TILT UP
PAN LEFT
PAN RIGHT
1
3
2
4
5
6
INVERTED MOUNTING
When the unit is mounted in the inverted position, the leftright directions are reversed for
manual operation. This must be corrected when wiring the cable between control unit and
the pan and tilt drive. Simply reverse leads going to terminals 3 and 4.
1