Lika SME11 User Manual Download Page 8

SME11 - SME21 - SME51

5.2 Reference “R”

With   ordering   code   "R"   and   in   combination   with 
LKM-1309.

6 Maintenance

The magnetic measurement system does not need 
any particular maintenance; please always consider 
it is a delicate electronic equipment and therefore it 
must be handled with care. From time to time we 
recommend the following operations:

Check   the   gap   between   sensor   and   magnetic 
scale along the measuring length. Wear of the 
machine may increase the tolerances.

The   surface   of   the   magnetic   scale   should   be 
cleaned periodically using a soft cloth to remove 
dust, chips, moisture etc.

7 Troubleshooting

The   following   list   shows  some   typical   errors  that 
occur   during   installation   and   operation   of   the 
magnetic measurement system.

Fault:

The system does not work (no pulse output).

Possible cause:

The   scale   or   sensor   has   been   mounted 
incorrectly (the active part of the scale does not 
match the sensor active side).

A   magnetic   piece   or   scale   is   in   between   the 
sensor   and   the   scale.   Only   non-magnetic 
materials are allowed between sensor and scale.

The sensor touches the scale because tolerance 
gap between sensor and scale is not respected. 
Check the sensor active side if damaged.

The sensor has been damaged by short circuit or 
wrong connection.

Fault:

The measured values are inaccurate.

Possible cause:

The   gap   between   sensor   and   scale   is   not 
respected along the whole measurement length.

The connection cable runs near to high voltage 
cable or shield is not connected correctly. See 
section “4 - Electrical connections“.

The max. counting frequency of your receiving 
device is too low.

A   section   of   the   magnetic   scale   has   been 
damaged   mechanically   or   magnetically   along 
the measuring length

The measuring error is caused by torsion of the 
machine   structure.   Check   parallelism   and 
symmetry of machine movement.

Release

Description

1.1

1st issue

1.2

Revised edition

1.3

Correction of section 3, revised edition

1.4

Add M12 connector (section 4)

Lika Electronic

Via S. Lorenzo, 25 - 36010 Carrè (VI) - Italy

Tel. +39 0445 806600
Fax +39 0445 806699

Italy : eMail [email protected] - www.lika.it
World : eMail [email protected] - www.lika.biz

MAN SMEx1 I_E 1.4.odt

8

www.lika.it

www.lika.biz

Summary of Contents for SME11

Page 1: ...delle norme di sicurezza da parte dell utilizzatore Avvertenze elettriche Effettuare le connessioni elettriche esclusivamente in assenza di tensione rispettare le istruzioni relative alle connessioni...

Page 2: ...e Distanza sensore banda D Distanza sensore copri banda D SME11 0 1 0 5 mm 0 1 0 3 mm SME21 0 1 1 3 mm 0 1 1 0 mm SME51 0 1 2 0 mm 0 1 1 7 mm 3 1 Montaggio sensore con Reference R Il LED R acceso indi...

Page 3: ...48 Km 2 x 90 Km La lunghezza massima di collegamento tra sensore ed elettronica di acquisizione non dovr superare i 50 m Per distanze maggiori contattare il personale tecnico di Lika Electronic 4 2 Co...

Page 4: ...ensore e banda magnetica es acciaio non amagnetico Durante il funzionamento il sensore venuto ripetutamente a contatto con la banda magnetica provocandone il guasto ispezionare la superficie attiva de...

Page 5: ...r l assumes no liability for the customer s failure to comply with these requirements Electrical safety Turn OFF power supply before connecting the device connect according to explanation in section 4...

Page 6: ...uge Figure 1 Sensor Gap Sensor Magnetic scale D Gap Sensor Cover strip D SME11 0 1 0 5 mm 0 1 0 3 mm SME21 0 1 1 3 mm 0 1 1 0 mm SME51 0 1 2 0 mm 0 1 1 7 mm 3 1 Mounting gap with Reference R The R Led...

Page 7: ...of the cable connecting the sensor and the receiving device should not exceed 50 m 55 Yd Should greater distances to be reached please contact Lika Electronic Technical Dept 4 2 GND connections Minimi...

Page 8: ...Only non magnetic materials are allowed between sensor and scale The sensor touches the scale because tolerance gap between sensor and scale is not respected Check the sensor active side if damaged Th...

Reviews: