Lika SME1 User Manual Download Page 2

 

SME1  SME2  SME5 

 

2  Identification 

 

The  sensor  can  be  identified  by  the  label's  data 
(ordering  code,  serial  number).    This  information  is 
listed  in  the  delivery  document.  All  technical 
features  according  to  the  ordering  code  are  shown 
on the catalogue. 

 

2.1 Sensor and tape combinations 

 

Sensor 

Magnetic tape 

SME1 

MT10 

SME2 

MT20 

SME5 

MT50 

 
 
 

3  Mounting instructions 

 

Sensor  can  be  fixed  by  means  of  two  M3  screws 
over the buttonholes.  
Make sure that the gap between sensor and tape is 
in  respect  with  (fig.  1)  along  the  total  measuring 
length.  Avoid  contact  between  the  parts.  You  can 
check planarity and parallelism between sensor and 
magnetic tape using a feeler gauge 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Sensor 

Gap Sensor/ 

Magnetic tape (D) 

Gap Sensor/ 

Protection   
profile (D) 

SME1 

0,1 < 0,4 mm 

0,1 < 0,2 mm 

SME2 

0,1 < 1,0 mm 

0,1 < 0,7 mm 

SME5 

0,1 < 2,0 mm 

0,1 < 1,7 mm 

 

 

3.1 Mounting gap with Reference “R” 

 

The Led ON indicates that the zero signal is enabled 
(distance between sensor and LKM1309 is correct).  
If the zero signal is not present on the output when 
Led  is  ON,  move  the  Reference  Mark  (LKM1309)  of 
about  half  pole  length  to  align  it  with  the  tape 
while keeping the same distance from the sensor. 
 
 
 
 
 
 
 
 
 
 
 
 
 

D:

   gap to be kept between sensor and LKM1309. 

D2:

  distance from the centre of fixing hole to the 

edge of Reference Mark. 

 

SMEx  LKM1309 

D2 

SME1 < LKM1309/1  0,1 < 0,3 mm 

7,3 mm 

SME2 < LKM1309/2  0,5 < 0,7 mm 

7,5 mm 

SME5 < LKM1309/5  0,5 < 1,0 mm 

7,5 mm 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Reviews: