EM58 • HS58 • HM58 POWERLINK
6.12.3 Standardised Device Profile Area objects (DS 406)
6000 Operating parameters
[Unsigned16, rw]
Bit
Function
bit = 0
bit = 1
0
CW
(clockwise)
CCW (counter
clockwise)
1
not used
2
disabled
enabled
3 … 13
not used
14
15
Default = 0000h
Code sequence
It defines whether the position value output by the encoder increases (count up
information) when the encoder shaft rotates clockwise (0 = CW) or counter-
clockwise (1 = CCW). If bit 0
= 0, the absolute position value
increases
when the encoder shaft rotates
clockwise
; on the contrary, if bit 0
= 1, the absolute position value
increases
when the encoder
shaft rotates
counter-clockwise
. CW and CCW rotations are viewed from the
shaft end.
WARNING
Changing this value causes also the position calculated by the controller to be
necessarily affected. Therefore it is mandatory to execute a new preset and save
the parameters after setting this parameter.
NOTE
is currently set to CW or CCW, you can
page 98.
Scaling function
If this function is disabled (bit 2
physical resolution to arrange the absolute position value (see the
= 1), the device uses the custom
6001 Measuring units per revolution
Total measuring range in measuring units
objects in compliance with the
following relation:
MAN EM58_HS58_HM58 PL E 1.1.odt
POWERLINK interface
91 of 108