LD220
Output polarity 4
Polarity for the switching condition of
. For complete
information please refer to the
parameter in the “6.7
Preselection 1 menu” section on page 61.
Output lock 4
Latch for the switching condition of
. For complete information
parameter in the “6.7 Preselection 1 menu”
section on page 61.
Start up delay 4 (s)
Start up delay setting for the switching condition of
. It is the
delay before starting the monitoring function.
This adjustment only applies to the switching conditions
1 - |RESULT|<=|
PRES|
and
4 - RESULT<=PRES
parameter on page 69). The
automatic start up suppression is activated when the parameter is switched on
and the display value is 0. The monitoring function remains deactivated until
the preset value / switching point is exceeded for the first time.
0 OFF
No start up delay setting
1 AUTO
Automatic start up delay setting, until the
preselection value / switching point is exceeded for
the first time.
NOTE
respectively) have a time-dependent start up delay setting.
Event color 4
Event-depending change of colour of the display for the switching condition of
highest priority and are allowed to overwrite the change of colour set next to
the
parameter. For complete information please refer to the
parameter in the “6.7 Preselection 1 menu” section on page 61.
MAN LD220 E 1.4.odt
6 – Menus and parameters
70 of 100