LD220
Error bit
It enables the error bit diagnostics and the position of the error bit. For more
information please refer to the “6.3.2.1 Checking the error bit” section on page
45.
0
No error bit available.
Diagnostics on the connected encoder is disabled.
...
32
Position of the error bit to be evaluated.
Diagnostics on the connected encoder is enabled.
Error polarity
This parameter sets the polarity of the error bit in case of error. For more
information please refer to the “6.3.2.1 Checking the error bit” section on page
45.
0
In case of error the bit has LOW logic level.
1
In case of error the bit has HIGH logic level.
Encoder supply
It allows to set the voltage level of the auxiliary voltage output (4 = Aux. Out).
For more information refer to the “4.3 Auxiliary voltage output” section on page
19.
0 24VDC SUPPLY
24 Vdc encoder supply
1 5VDC SUPPLY
5 Vdc encoder supply