register and activate it by sending the command
(set “02” in the register 48).
Default =
05h
.
Preset / Offset
[51 … 53, rw]
This function is available only if the
register is set to ENABLE. Furthermore it has a double function
register is set to PRESET or OFFSET. In the first case (
register is used to set the preset value; while in the
second case (
to set the offset value.
WARNING
Activate the preset / offset value only when the device is not moving.
Preset
The preset function is meant to assign a value to a desired physical position of
the sensor. The chosen physical position will get the value set next to this item
and all the previous and following positions will get a value according to it. This
function is useful, for example, when the zero position of the sensor and the
zero position of the axis need to match. The preset value will be set for the
position of the sensor in the moment when the preset value is activated. To
activate the preset, stop the sensor in the desired position, enter the desired
value next to this
command in the
register (set “02” in the register 48).
Offset
The offset function is meant to assign a value to a desired physical position of
the sensor so that the output position information is shifted according to the
value set next to this
register. The number of transmitted values
will match the maximum number of position information as per the set
resolution, but the output information will range between the
value (minimum value) and the sum of the max. position information as per the
set resolution (see the
value (maximum value). The offset value will be set for the position of the
sensor in the moment when the offset value is activated. To activate the offset,
stop the sensor in the desired position, enter the desired value next to this
Save and activate Preset / Offset
register (set “02” in the register 48).
MAN SMA1 E 2.9.odt
6 - BiSS B-mode interface
27 of 48