background image

MC150

5.5 J1 jumper (encoder power supply)

Position

Function

Left

+10Vdc +30Vdc 

*

Right

+5Vdc

*

: see chapter “5.2 CON2 connections”.

5.6 J2 jumper (input signal level)

Position

Function

Left

Input connected with GND (CON3/Pin9)

Right

Input connected with +24Vdc 

(CON3/Pin10)

6 - Functions

6.1 Start up

At  start up the  unit  shows  the  software  version 
followed by actual position.
Software version: 

SOF xx

6.2 Key functions

Key

Function

F

Function (save + exit setup)

Shift Right (select parameter / digit)

Up (change value)

E

Enter (save + scroll menu)

6.2.1 Default parameter

 (factory settings)  

Default   parameter   values   are   written   in  

BOLD 

characters. The unit can be reset to default values 
by pushing

 F

 and 

E

 key while switching on.

6.2.2 Direct functions

To set direct functions,  such as  reset, reset with 
datum   value,   tool   correction   (offset   value), 
absolute/relative display mode and mm/Inch display 
mode, program 

P07

 parameter.

7 - Set up

7.1 Access to setup menus

Push 

F

 key to enter setup.

push 

 to select 

Func 1

 or 

Func 2

push 

E

 to scroll parameters

push 

F

 to exit setup

Admissible value range for each parameter is listed 
as follows: [min. value, max. value]

7.2 Parameter setting

In order to activate modified parameters, switch off 
and on the device.

Level 1: Func1
P00

 Datum value / Eich [-99999, 999999]

Display can be set to datum value (or preset) by 
activating SET input or pushing 

 key.

Default value: 

50.0

Level 2: Func2
P00

 Display value per distance moved [1, 10000]

Enter   the   value   to   be   displayed   when   the   unit 
receives the number of pulses per distance moved 
in   parameter   P01.   Note   this   value   is   entered 
without decimal.
Default value: 

100

 

P01

 Nr. of pulses per distance moved [1, 65000]

Enter the number of pulses per distance. This same 
distance unit is used to determine the Display value 
per distance moved.
Default value: 

100

Example:

A   ball   screw   moves   12.3mm   per   revolution.   The 
system uses a rotary encoder with 200 PPR (pulses 
per revolution). 
In this case:
P00 should be set to 123 (value without decimals) 
P01 is 200

MAN MC150 I_E 1.7

11

www.lika.it

www.lika.biz

 

Summary of Contents for MC150 series

Page 1: ...voltage power cables e g drive cables Install EMC filters on sensor power supply if needed Avoid mounting sensor near capacitive or inductive noise sources such as relays motors and switching power s...

Page 2: ...Pin 4 N max 100 mA Pin 5 P E 5 2 CON2 connections sensor input Pin Function 1 GND 2 24Vdc J1 left power supply 24Vdc 12Vdc J1 left power supply 115Vac 230Vac 5Vdc J1 right any power supply 3 A 4 A see...

Page 3: ...ss to setup menus Push F key to enter setup push to select Func 1 or Func 2 push E to scroll parameters push F to exit setup Admissible value range for each parameter is listed as follows min value ma...

Page 4: ...estore default value see chapter Default parameter 6 2 1 P07 Function of the push buttons 0 6 The function of the and the E buttons in operating mode can be selected 0 no functions 1 E will set actual...

Page 5: ...6 Output configuration 0 1 0 static output 1 with output dwell time see P17 and P18 P17 Output 1 dwell time 0 2 50 Enter output dwell time between 0 and 2 50 seconds P16 must be 1 Default value 0 P18...

Page 6: ...ion in sec P62 must be 1 Default value 1 00 P99 Actual value for RS232 99999 999999 This parameter shows the actual value for serial transmission via RS232 Interface if parameter P62 0 NOTE In order t...

Page 7: ...smission is correct slave replies with ACK in any other cases with NAK MC150 PC ACK or NAK All parameters sent to the slave are stored in a data buffer Parameters have to be activated by the activate...

Page 8: ...the following data string will be transmitted MC150 printer AD1 AD2 DATA LF CR xx xx xx 0A Hex 0D Hex The MC150 is sending its serial address followed by the actual value and Line Feed LF and Carriage...

Reviews: