EM58 – HS58 - HM58 MODBUS TCP/IP
Warnings register [123-124]
[122-123, Unsigned16, ro]
This variable is meant to show the warnings currently active in the device. No
warnings are supported in this encoder.
Wrong parameters list [125-126]
[124-125, Unsigned16, ro]
The operator has entered invalid data and the
has been triggered. This variable is meant to show (bit value = HIGH) the list of
the wrong parameters, according to the following table.
Please note that the normal work status can be restored only after having set
proper values.
Bit
Function
bit = 0
bit = 1
0
Alarm not active
Alarm active
1
Alarm not active
Alarm active
2
Alarm not active
Alarm active
3
Alarm not active
Alarm active
4 … 31
not used
Byte 0
Counts per revolution error
bit 0
Wrong data has been set next to the
registers. Set proper values to
restore the normal work condition.
Total resolution error
bit 1
Wrong data has been set next to the
registers. Set proper values to restore the
normal work condition.
Preset value error
bit 2
Wrong data has been set next to the
registers. Set proper values to restore the normal work
condition.
Offset value error
bit 3
Wrong data has been saved on the
registers. Save proper values to restore the normal
work condition.
bits 4 … 7
Not used.
MAN EM58_HS58_HM58 MT E 1.1.odt
Programming parameters
65 of 104