EM58 – HS58 - HM58 MODBUS TCP/IP
3.2.3 EMC60, HSC60, HMC60
•
Remove the anti-rotation pin
1
(see the Figure on page 22);
•
fix the tempered pin
6
to the rear of the motor;
•
mount the encoder on the motor shaft using the reducing sleeve
8
(if
supplied). Avoid forcing the encoder shaft;
•
make sure the anti-rotation pin
6
is inserted properly into the fixing plate
7
;
•
fix the collar
3
to the encoder shaft (apply some threadlocker to the screw
3
).
NOTE
You are strongly advised not to carry out any mechanical operations (drilling,
milling, etc.) on the encoder shaft. This could cause serious damages to the
internal parts and an immediate warranty loss. Please contact our technical
personnel for the complete availability of "custom made" shafts.
MAN EM58_HS58_HM58 MT E 1.1.odt
Mounting instructions