5.1 Output signals level

The   voltage   level   refers   to   the   differential   value 
between normal and inverted signal (differential).

Recommended input circuit

   Encoder

Input circuit

V

REF

 = 2,5V ± 0,5V      V

A

 = 1Vpp · Av      Av = R2/R1

Document 

release

Description

1.0

1st issue

1.1

Added example in section 5

1.2

Updated paragraph 6.1

1.3

Updated section 4

1.4

Updated sections 1, 3.1 and 4

1.5

Added CB60

1.6

Updated section 4

1.7

Updated section 4

1.8

Updated sections 1 and 3.1

1.9

Added CB61

1.10

Updated section 4

1.11

Updated section 3

This   device   is   to   be   supplied   by   a   Class   2 
Circuit   or   Low-Voltage   Limited   Energy   or 
Energy Source not exceeding 30VDC. Refer to 
the product datasheet for supply voltage rate.

LIKA Electronic

Via S. Lorenzo, 25 - 36010 Carrè (VI) - Italy

Tel. +39 0445 806600
Fax +39 0445 806699

Italy: eMail [email protected] - www.lika.it
World: eMail [email protected] - www.lika.biz

MAN CB59_CB60_CB61 I_E 1.11.odt

8

www.lika.it

www.lika.biz

 

Summary of Contents for CB59

Page 1: ...one rispettare le istruzioni relative alle connessioni riportate nella sezione 4 Connessioni elettriche i fili dei segnali d uscita non utilizzati devono essere isolati singolarmente in conformit alla...

Page 2: ...vimenti di parti meccaniche Non eseguire lavorazioni meccaniche sul dispositivo 3 1 Montaggio dell encoder Per il montaggio dell encoder necessario che l albero motore disponga di un foro filettato pe...

Page 3: ...G Schermo Rame intrecciato Diametro esterno 5 4 mm 0 1 Resistenza elettrica 242 Ohm Km 20 C UL 758 tab 5 2 1 Cavo TF12 Funzione Marrone_Verde VDC Bianco_Verde 0VDC GND Rosso A Nero A Verde B Marrone B...

Page 4: ...one 4 1 7 Correzione sezione 4 1 8 Correzione sezioni 1 e 3 1 1 9 Aggiunto CB61 1 10 Corretto cavo TF12 1 11 Aggiornamento sezione 3 Il dispositivo deve essere alimentato da un circuito di Classe 2 da...

Page 5: ...comply with these requirements Electrical safety Turn OFF power supply before connecting the device connect according to explanation in section 4 Electrical connections wires of output signals which a...

Page 6: ...disconnected and mechanical parts absolutely in stop Do not tool the unit 3 1 Installing the encoder For correct installation a M5 threaded bore has to be provided in the motor shaft see Figures belo...

Page 7: ...irs 6 x 2 x 28AWG Shield braided copper Outside 5 4 mm 0 1 Impedance 242 Ohm Km 20 C UL 758 tab 5 2 1 TF12 Cable Function Brown_Green VDC White_Green 0VDC GND Red A Black A Green B Brown B Violet C Ye...

Page 8: ...s 1 3 1 and 4 1 5 Added CB60 1 6 Updated section 4 1 7 Updated section 4 1 8 Updated sections 1 and 3 1 1 9 Added CB61 1 10 Updated section 4 1 11 Updated section 3 This device is to be supplied by a...