SFA-5000 • SFA-10000 CANopen®
Default = 01h
Master
Encoder
COB-ID
Cmd
Index
Sub
Data byte
600+ID
2F
01
30
00
new Node-ID
Encoder
Master (confirmation)
COB-ID
Cmd
Index
Sub
Data byte
580+ID
60
01
30
00
00
Master
Encoder (
Reset node
)
COB-ID
Cmd
Slave ID
000
81
old ID
Encoder
Master (Boot-up with new Node-ID)
COB-ID
Cmd
700+ID
00
NOTE
To save the new Node-ID value execute the store parameters function (see the
object).
When the power is turned off, the parameters not saved are lost.
3005-00 Velocity format
[Unsigned8, rw]
This attribute defines the engineering units for the velocity value.
00h = steps/s: number of steps per second (default);
01h = rpm:
number of revolutions per minute.
Default = 00h
3006-00 Velocity value
[Unsigned32, ro]
This attribute shows the current output speed value detected by the position
sensor and calculated every 100 ms.
The value can be expressed in either steps per second or revolutions per minute
according to the setting in the previous
object.
The value is transmitted according to the settings in the
object.
MAN SFA_5000_10000_CB E 1.0.odt
6 - CANopen® interface