background image

Quick Start Guide

UMX4x4-Pro2

Further information

The document is valid with the following firmware version: 2.0.3

 

The User’s manual of this appliance is available on 

www.lightware.eu

.

 

See the 

Downloads

 section on the website of the product.

Contact us

[email protected]

+36 1 255 3800

[email protected]

+36 1 255 3810

Lightware Visual Engineering LLC.

Peterdy 15, Budapest H-1071, Hungary

Doc. ver.: 1.0

 

19200032

Important safety instructions

Please read and keep the information in the attached safety instructions supplied with the 

product before starting using the device.

Introduction

Lightware’s UMX4x4-Pro2, the all-round universal matrix switcher with four inputs and four 

outputs, is the perfect solution for ever-changing environments such as small board rooms 

and classrooms. UMX (Universal MatriX) technology was developed by Lightware to support 

various analog and digital audio visual formats. VGA, YUV, digital DVI, HDMI with HDCP, 

stereo analog, and S/PDIF digital audio signals are all supported.

Box contents

Switching operations

1. First, press and release the desired 

source button

The pressed source button and all destination buttons 

which are currently connected to the source lights up.

SOURCES

DESTINATIONS

2. Press and release the desired 

destination buttons

 

which have to be (dis)connected to/from the selected 

source. The preselected destination buttons will blink.

SOURCES

DESTINATIONS

3. Press and release 

Take

 button; the selected input is 

switched to the selected output(s).

Lock an output

1. Press and release the 

Output Lock

 button; it starts to 

blink and all the buttons of any locked destinations light 

up (view state).

OUTPUT

LOCK

CONTROL

LOCK

SOURCES

DESTINATIONS

2. Press and release a 

destination button

; it starts to 

blink (more destinations can be selected sequentially).

OUTPUT

LOCK

CONTROL

LOCK

SOURCES

DESTINATIONS

3.  Press  and  release  the 

Take

  button.  The  selected 

destinations are now locked.

Front panel controls in TAKE mode

Take

 mode allows the user to connect or disconnect multiple outputs to an input 

at once. This mode is useful when the time delay is not allowed between multiple 

switching. The commands are only realized when the 

Take

 button is pressed.

LOAD

PRESET

SAVE

PRESET

TAKE
AUTO

LOAD

PRESET

SAVE

PRESET

TAKE
AUTO

Switching operations

1.  Press  and  release  the  desired 

destination

 

button

The  pressed  destination  button  and  the  actually 

connected source button light up green. If no source is 

connected  (the  output  is  muted)  no  source  button  will 

light up.

SOURCES

DESTINATIONS

2. Press and release the desired 

source button

. The 

switch  action  will  be  executed  immediately.  Switching 

between sources to the selected destination can be done 

directly.

SOURCES

DESTINATIONS

Lock an output

1. Press and release the required 

destination button

Now the selected destination button and  the currently 

configured source button light up (view mode).

OUTPUT

LOCK

CONTROL

LOCK

SOURCES

DESTINATIONS

2. Press and release the 

Output Lock

 button; it lights up 

in red, and lock function is activated at once. No source 

can be changed at the locked destination.

OUTPUT

LOCK

CONTROL

LOCK

SOURCES

DESTINATIONS

Front panel controls in AUTOTAKE mode

Autotake

 mode is useful when immediate actions must be done or fast switching 

is needed between sources on a particular destination. In this mode switching 

occurs immediately upon pressing one of the input selector buttons.

 Pay attention to the states of the Signal layer buttons which determine the layers when 

executing switching or locking operations.

Mounting with front rack ears

The front rack ears allow mounting the device 

as a standard rack unit installation.

Ventilation

 To ensure the correct ventilation and 

avoid overheating let enough free space 

around the appliance. Do not cover the 

appliance, let the ventilation holes free on 

both sides.

The cooling of the device is ensured by convection only.

Powering on

Connect the power cord to the device’s IEC C14 standard power input connector. The router 

is immediately powered ON when the power cord is connected to the AC source. The matrix 

beeps two times and 

Booting…

 appears on the LCD screen while the initial self-test is run. 

Last configuration is reloaded and the appliance is ready to use. In the case of a hardware 

failure, an error message is displayed.

 After switching ON, the router reloads the latest settings that were used before it was 

turned off. The router has an internal emergency memory that stores all current settings and 

tie configurations. This memory is independent from presets and invisible for the user. This 

built-in feature helps the system to be ready immediately in the case of a power failure or 

accidental power down.

UMX4x4-Pro2

matrix switcher

IEC power cable

LAN cross-link cable,

 

CAT5e type, 3m length

RS-232 straight

serial cable

Safety and warranty info, 

Quick Start Guide

VGA to DVI-D

adapter cable (4x)

Front view

1

Control lock

Disables  or  enables  front  panel  operations.  Red  light 

means the switching and function buttons are disabled.

2

Sources

Buttons to select an input, to select a preset number or to 

view the state of the selected input port.

3

Layer selection

Audio and video signals are placed on different layers so 

they can be switched separately or at the same time. Layer 

select buttons choose the desired signal(s) to be switched.

4

Take button

Switching  between  Take  and  Autotake  working  modes; 

keep the button pressed for 3 seconds to toggle the modes.

5

Preset buttons

Performing preset operations (Load and Save).

6

Display

2x16 character LCD display for menu operations.

7

Menu navigation

Up, down, left, right and enter buttons.

8

Status LEDs

Power LED indicates that the unit is powered on and CPU 

LIVE blinking LED indicates normal operation.

9

Output lock

Lock and protect one or more outputs.

q

Destinations

Buttons to select an output or to see the state of an output.

w

EDID button

The EDID mode can be (de)activated by the button.  Use 

this mode to set up the emulated EDID on the inputs, learn 

EDID form the outputs, or to view the EDID memory. The 

illuminated button shows that the mode is active.

e

Signal present

This  Signal  present  mode  can  be  (de)activaed  by  the 

button. Use this mode to check the presence of the display 

devices  and  incoming  signals.  The  illuminated  button 

shows that the mode is active.

Rear view

1

AC connector

Standard IEC connector accepting 100-240 V, 50 or 60 Hz.

2

Fuse

Replace with F 3.15AL type only when necessary.

3

Inputs

UMX4x4-Pro2 has 4 input ports. Each port has a video, an 

analog stereo audio, and a digital audio input.

4

DVI-I input

Standard 29 pole DVI-I connectors for input connections 

accepting analog and digital signals.

5

S/PDIF input

RCA jack connector for S/PDIF digital audio signal.

6

Analog audio 

input

Double RCA jack connector for unbalanced, analog stereo 

audio input signal (left and right channels).

7

Outputs

UMX4x4-Pro2 has 4 output ports. Each port has a video, 

an  unbalanced  analog  stereo  audio,  and  a  digital  audio 

output.

8

DVI-D output

Standard 29 pole DVI connectors for outputs - only digital 

pins are connected.

9

S/PDIF output

RCA  jack  connector  for  S/PDIF  digital  audio  signal. 

Embedded audio is still present on the DVI-D outputs.

q

Analog audio 

output

Double RCA jack connector for unbalanced, analog stereo 

audio output signal (left and right channels).

w

Reset button

Reboots the matrix (the same as disconnecting from the 

power source and reconnecting again).

e

Ethernet port

Standard RJ45 connector. This port can be connected to a 

computer directly or to LAN via switch or router.

r

RS-232 port

9 pole D-sub female connector for standard RS-232 port.

CONTROL LOCK

If the button illuminates in 

red

 the switching- and function buttons are disabled. 

Press and hold the 

Control lock 

button for three seconds to toggle the state.

 When the front panel buttons are locked, remote control (RS-232, USB, 

Ethernet) is still available.

LCD menu - navigation

Front panel LCD has 2 lines and 16 characters in each line. The name of the menu item is 

always displayed in the first line.

Signal layers

Video and audio signals are in different layers. It means video and audio signals can be 

switched separately or together. At least a layer is selected all the time. Therefore, the currently 

selected layer buttons are illuminated. To toggle between the layers’ on and off state press 

the VIDEO and/or the AUDIO signal layer buttons. Before every operation which effects input 

and output signals (e.g. switching, muting, locking, etc.) the desired layer should be selected.

 

(up)

toggle between menu items

(down)

toggle between menu items

(left)

move the cursor or step back to previous menu

(right)

move the cursor

ENTER

execute changes or enter a submenu

Network settings on the front panel

Setting a dynamic IP address

1. 

Navigate to the 

IP settings 

item  and  press  the 

enter

 button.

2. 

Use the 

up

 and 

down

 buttons to toggle between 

the

 

options; set to 

Enabled

.

3.  Press the 

enter

 button to save changes.

4. 

Navigate to the 

Save & Exit 

item with the 

left

 and 

right

 buttons, then press the 

enter

 

button.

Setting a static IP address

1.  Disable the 

DHCP 

setting as described above.

2. 

Use the 

left 

and 

right

 buttons to select the octet; 

change the value by the 

up

 and 

down

 buttons.

3.  To apply the settings press the 

enter

 button.

4. 

Navigate to the 

Save & Exit 

item with the 

left

 and 

right

 buttons, then press the 

enter

 button.

 New IP settings can be applied while an active connection is alive on the Ethernet port but 

in this case, the active connection will be closed automatically. Establish the connection again 

to reconnect the Ethernet port.

IP ADDR fixIP
192.168.000.105

IP ADDR DHCP

CONTROL

LOCK

Safety and

warranty

info

Quick

Start

Guide

TAKE
AUTO

TAKE
AUTO

1

2

5

6

8

7

9

q

3

4

w e

1

3

2

5

7

9

8

w e

r

6

q

4