MODEX-OPTS, MODEX-OPTM
User’s Manual
Section 6. Web control
– Using the built-in website
Page 57 / 113
The action is the “reply” if the condition becomes true. There is no sequence between the
condition and the action. Either of them can be set firstly.
Step 4.
To set the action, click on the wizard button on the action side.
The process is the same. Click on the down arrow of the drop-down menu than select the
desired item. The category and the expression can be set. If the expression requires further
parameter, select it. E.g. if the Expression is a switching on the video layer, the input and
the output port has to be selected in the next step.
Step 5.
Click on the OK to finish the wizard of the action.
The window of the wizard is closed; the created action can be seen above the buttons. The
white text is the name of the selected action, the yellow is the accurate property (and its
value) or method name by LW3 protocol. You do not need to remember or note this text,
LDC shows it continuously. The system checks the validity of the event. If everything is
correct, a green line can be seen at the bottom of the event area.
6.8.3. Advanced mode
The goal of this mode is the same as of the wizard: set the properties and methods for
conditions and actions. The difference is the number of the available and usable properties
and methods of the LW3 protocol. Advanced mode allows almost all of it.
Step 1.
Click the Advanced button. A new window comes up.
Step 2.
Select the desired node and the property; on the left side there is the closed LW3
tree of the device. To open it, click on the plus sign (in the red square).