5. Software Control – Lightware Device Controller
MMX6x2-HT series – User's Manual
43
5.11.
Settings Menu
5.11.1.
Status Tab
General information is shown on this tab, such as device label, part number, serial number and hardware
health, voltage and temperature values.
Status Tab
5.11.2.
Network Tab
Network-related settings are available on the tab.
Network Tab
When dynamic IP address is used, the DHCP option is ticked; the IP settings of the matrix is shown in the
first three lines. When static IP address is used, the DHCP option shall be unticked and below three lines can
be used to define the IP settings. The device is able to communicate with LW2 and LW3 protocols, the ports
can be set in the displayed lines.
ATTENTION!
Connecting to the matrix via Ethernet and using LW2 port no. (default is 10001) the device
will accept LW2 protocol commands. Using LW3 port no. (default is 6107) the device will accept LW3
protocol commands.