Electrical safety
●
Check all electrical connections are isolated and that there are no exposed wires.
●
Make sure the power supplied to the device does not exceed the maximum rated voltages which are specified in
the technical specifications section.
●
The electrical wiring layout of this device is provided in the hardware section.
Mechanical safety
●
Ensure that there is adequate airflow permitted for the sensor.
●
The mechanical dimensions for mounting the LW24/C are provided in the hardware overview.
Laser radiation information
Specification
Value/AEL
Notes
Eye safety classification
Class 1M
Laser wavelength
905 nm
Pulse width
16 ns
Pulse frequency
20 kHz
Average power
< 2.5 mW
NOHD
15 m
Distance beyond which binoculars
may be used safely.
Approximate values only. Please contact LightWare LLC if further information is required.
Service & maintenance
The LW24/C is not field serviceable. For any repairs, the equipment should be completely isolated, removed then
packaged carefully. Please visit LightWare LLC’s
for Return Merchandise Authorization (RMA) details, or
contact
Cleaning
Use a dry and clean microfiber cloth to gently wipe across the lenses of the sensor, taking care not to scratch the
surface of the lenses.
LW24/C/SI microLiDAR™ sensor - Product guide
|
Version 0
|
03 March 2022
Page
19
of
36