OUTPUT CHANNEL CONNECTIONS 
 
The RE-82 is supplied with one of several rear panel output options.  Channel output connections are according 
to the the rear panel selected.  Channel connections generally proceed from left to right (if you are facing the rear 
of the unit).  Channel “A” will be on the left end.  Connections for load Neutrals are provided. There is also a 
ground lug terminal to be used for your load circuits grounds. 
 

OPERATION 

 
CHANNEL ASSIGNMENT 
 
The starting channel of each RE-82 is selected using the DIP switches on the front panel.  The diagram below 
indicates the actual value of each DIP switch position.  A chart at the end of this manual "CHANNEL 
ASSIGNMENT SWITCH SETTINGS" provides further information for setting the starting address DIP switches. 
 
 
 
 
 
 
 
 
 
 
 
Any switch in the up position ADDS the associated value to the starting channel number. All switches down = 
starting channel number 1.  
 
For example: to set the starting channel to 13, move the 2nd switch from the right (value 8)  and the 1st switch 
from the right (value 4) to the up position. For a starting channel of 21, move the third  switch from the right (value 
16)  and the rightmost switch (value 4) to the up position.   
 
MANUAL CONTROL 
 
Dimmer channels can be activated manually by pressing corresponding  button switches located on the front 
panel. This will latch the associated channel to full on.  Push the button again to turn the channel off. The 
associated LED will light when the channel is activated. 
 
NORMAL OPERATION 
 
LEDs located on the front panel of the RE-82 indicate channel levels as you operate faders on your console. The 
"VALID SIGNAL" LED will light whenever the dimmer is receiving a control signal within the range of channels 
that the dimmer is assigned to. The "Phase A" and "Phase B" LEDs will indicate that power sources are applied to 
the dimmer. The fan will run continuously whenever power is applied to the RE-82. An over-temperature sensor 
will shut down all channel output if the dimmer temperature rises above safe limits (

175

°

F exit air temperature). 

 
RELAY MODE 
 
The two leftmost switches control the "relay" mode. When either switch is in the up position, the channels 
associated with that switch operate in non-dim mode. These channels will be either full on or full off depending on 
the level of the faders controlling them. 
 
 
 

256  128   64   32   16   8   4  

ON 
 
 
OFF

 A-D E-H 

ADDRESS 

UP FOR RELAY MODE

 

Summary of Contents for RE82L

Page 1: ...www lightronics com Lightronics Inc 509 Central Drive Virginia Beach VA 23454 TEL 757 486 3588 RE 82 RACK MOUNT DIMMER 8 X 2400Watts OWNERS MANUAL Revision 2 4 11 29 2007 ...

Page 2: ... dimmers are to be installed into a standard 19 equipment rack with provisions for connection to an appropriate electrical service in accordance with the National Electrical Code LIGHTING LOAD CAPACITY Each RE 82 channel has a 2400 Watt MAXIMUM rating and is protected by a fast acting 20 Amp circuit breaker 20 Amps equates to 2400 Watts at 120VAC If you operate a channel at 2400 watts then you are...

Page 3: ...ch protocol can be used DMX CONTROL The DMX 512 control signal enters the RE 82 through a 5 pin XLR connector on the rear of the unit A second connector 5 pin female XLR is used to continue this control signal out to other dimmers in the system Normally the male connector is used for the incoming control signal and the female connector is used to loop out to other dimmers These connectors are wire...

Page 4: ...st switch from the right value 4 to the up position For a starting channel of 21 move the third switch from the right value 16 and the rightmost switch value 4 to the up position MANUAL CONTROL Dimmer channels can be activated manually by pressing corresponding button switches located on the front panel This will latch the associated channel to full on Push the button again to turn the channel off...

Page 5: ...sses are correctly set Check that the console is powered and that console channels are correctly patched or set Check the control cable between the dimmer and its console Verify the loads and their connections OWNER MAINTENANCE There are no user serviceable parts inside the unit The best way to prolong the life of your unit is to keep it cool clean and dry It is important that the cooling intake a...

Page 6: ... ØØØØØØÃ 5 ØÃØØØØÃ 133 ÃØØØØØÃ 261 ÃÃØØØØÃ 389 ØØØØØÃØ 9 ØÃØØØÃØ 137 ÃØØØØÃØ 265 ÃÃØØØÃØ 393 ØØØØØÃÃ 13 ØÃØØØÃÃ 141 ÃØØØØÃÃ 269 ÃÃØØØÃÃ 397 ØØØØÃØØ 17 ØÃØØÃØØ 145 ÃØØØÃØØ 273 ÃÃØØÃØØ 401 ØØØØÃØÃ 21 ØÃØØÃØÃ 149 ÃØØØÃØÃ 277 ÃÃØØÃØÃ 405 ØØØØÃÃØ 25 ØÃØØÃÃØ 153 ÃØØØÃÃØ 281 ÃÃØØÃÃØ 409 ØØØØÃÃÃ 29 ØÃØØÃÃÃ 157 ÃØØØÃÃÃ 285 ÃÃØØÃÃÃ 413 ØØØÃØØØ 33 ØÃØÃØØØ 161 ÃØØÃØØØ 289 ÃÃØÃØØØ 417 ØØØÃØØÃ 37 ØÃØÃØØÃ 165 ÃØ...

Page 7: ...es not cover loss or damage direct or indirect arising from the use or inability to use this product F Lightronics reserves the right to make any changes modifications or updates as deemed appropriate by Lightronics to products returned for service Such changes may be made without prior notification to the user and without incurring any responsibility or liability for modifications or changes to e...

Page 8: ...www lightronics com Lightronics Inc 509 Central Drive Virginia Beach VA 23454 TEL 757 486 3588 ...

Reviews: