Lightronics FXPAR4 Owner'S Manual Download Page 2

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   Page  2 of  3 

FXPAR4 MULTIPLE LENS PAR FIXTURE 

 

Version 1.1   

 

 

 

 

 

 

 

 

     

OWNER’S MANUAL   

 

 

 

 

 

 

 

 

 

 02/08/2022 

www.lightronics.com 

Lightronics Inc.   

 

 

 

 

 

 

 

 

509 Central Drive, Virginia Beach, VA  23454 

 

 

 

 

 

 

   757 486 3588 

locking knob and adjust as needed. Ensure that the 
locking knob is tightened down when finished. 
 

POWER CONNECTIONS 

 

 
The unit is supplied with a power cable and may be 
provided with a power cable connector. The GREEN 
/ YELLOW conductor in the power cable is 
connected to the fixture case as a safety ground.  
This conductor must be used if installing an alternate 
cable connector. 
 

LAMP REMOVAL / INSTALLATION 

 
The  FXPAR4  fixture uses an OSRAM GLA/575 or 
GLE/750 (G9.5 Base) lamp.  Before installing a 
lamp, verify that the lamp is compatible with the 
voltage at your facility. Operating lamps beyond their 
rated voltage reduces lamp life and can cause other 
lamp failures. 
 

Disconnect all power from the fixture. 
 
Allow the fixture to cool off before proceeding.  
 
Keep the lamp and lens clean. Do not touch the 
lamp or lens with your bare hands. 
 
LAMP REMOVAL 

 
1.  Remove the lamp holder from the main housing 
 

using the knurled knob at the rear of the fixture. 

 
2.  Do not touch the glass envelope of the lamp.  
 

Remove the lamp from the lamp holder by pulling 

 

it straight out of the lamp holder socket. 

 
LAMP INSTALLATION 

 
1.  Remove the lamp holder from the main housing 
 

using the knurled knob at the rear of the fixture.

 

 
2.  Insert the lamp in the lamp holder socket. Do not 
 

touch the lamp glass envelope with your fingers. 

 

 

Do not operate the lamp unless the lamp holder 
 

is installed in the fixture! 

 
3.  Install  the lamp holder in the main housing and 

 

tighten the knob. 

 
LENS REMOVAL / INSTALLATION 

 
The  FXPAR4  contains a lens rotation ring which is 
located near the front of the housing.  The lens is 
held in place by two small fixed tabs on one side of 
the lens rotation ring and a larger metal release tab 
on the other side. 

 
Disconnect all power from the fixture. 
 
Allow the fixture to cool off before proceeding.  
 
Do not remove or install the lens while the unit is 
hanging up.  The lens can easily fall out if 
released. 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

LENS REMOVAL 

 
1.  Place the fixture on a horizontal surface with the 
 

lens down. 

 
2.  Turn the lens rotation ring until the metal release 
 

tab is 90º away from the gel retaining clip on the 

 

housing. 

 
3.  Hold one hand under the lens and press the 

metal  release tab to release it.  Allow the lens to 
carefully  drop out of the fixture. 

 

LENS INSTALLATION 

 
1.  Place the fixture on a horizontal surface. 
 
2.  Turn the lens rotation ring until the metal release 
 

tab is 90º away from the gel retaining clip on the 

 

housing. 

 
3.  Slide the one edge of the lens edge under the 

fixed   tabs on the lens rotation ring. 

 
4.  Press the other edge of the lens down until it is    

CAUTION 

RISK OF ELECTRIC SHOCK 

The fixture must be correctly 

grounded and must be 

installed to comply with all 

applicable regulations. 

Rotation Ring 

Release Tab 

Reviews: