locking knob and adjust as needed. Ensure that the
locking knob is tightened down when finished.
POWER CONNECTIONS
The unit is supplied with a power cable and may be
provided with a power cable connector. The GREEN
/ YELLOW conductor in the power cable is
connected to the fixture case as a safety ground.
This conductor must be used if installing an alternate
cable connector.
LAMP REMOVAL / INSTALLATION
The FXPAR4 fixture uses an OSRAM GLA/575 or
GLE/750 (G9.5 Base) lamp. Before installing a
lamp, verify that the lamp is compatible with the
voltage at your facility. Operating lamps beyond their
rated voltage reduces lamp life and can cause other
lamp failures.
Disconnect all power from the fixture.
Allow the fixture to cool off before proceeding.
Keep the lamp and lens clean. Do not touch the
lamp or lens with your bare hands.
LAMP REMOVAL
1. Remove the lamp holder from the main housing
using the knurled knob at the rear of the fixture.
2. Do not touch the glass envelope of the lamp.
Remove the lamp from the lamp holder by pulling
it straight out of the lamp holder socket.
LAMP INSTALLATION
1. Remove the lamp holder from the main housing
using the knurled knob at the rear of the fixture.
2. Insert the lamp in the lamp holder socket. Do not
touch the lamp glass envelope with your fingers.
Do not operate the lamp unless the lamp holder
is installed in the fixture!
3. Install the lamp holder in the main housing and
tighten the knob.
LENS REMOVAL / INSTALLATION
The FXPAR4 contains a lens rotation ring which is
located near the front of the housing. The lens is
held in place by two small fixed tabs on one side of
the lens rotation ring and a larger metal release tab
on the other side.
Disconnect all power from the fixture.
Allow the fixture to cool off before proceeding.
Do not remove or install the lens while the unit is
hanging up. The lens can easily fall out if
released.
LENS REMOVAL
1. Place the fixture on a horizontal surface with the
lens down.
2. Turn the lens rotation ring until the metal release
tab is 90º away from the gel retaining clip on the
housing.
3. Hold one hand under the lens and press the
metal release tab to release it. Allow the lens to
carefully drop out of the fixture.
LENS INSTALLATION
1. Place the fixture on a horizontal surface.
2. Turn the lens rotation ring until the metal release
tab is 90º away from the gel retaining clip on the
housing.
3. Slide the one edge of the lens edge under the
fixed tabs on the lens rotation ring.
4. Press the other edge of the lens down until it is
CAUTION
RISK OF ELECTRIC SHOCK
The fixture must be correctly
grounded and must be
installed to comply with all
applicable regulations.
Rotation Ring