background image

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    Page 2 of 4   

 

 

 

 

 

 

 

 

 

 

 

 

FXLD618FR2I LED FIXTURE 

 

Version 1.1   

 

 

 

 

 

 

 

 

 

OWNER’S MANUAL   

 

 

 

 

 

 

 

 

    

05/11/2022 

www.lightronics.com 

Lightronics Inc.   

 

 

 

 

 

 

 

509 Central Drive, Virginia Beach, VA 23454  

 

 

 

 

 

 

   757 486 3588

 

OPERATION 

 

A control panel on one side of the unit is used to set 
the operating options.  It consists of an LED display 
and four buttons (MENU, UP, DOWN, and ENTER). 
 

 
 
 
 
 
 
 
Push MENU to access the operating options. Then use 
UP and DOWN to scroll through the available choices.  
When you reach the option you want to set or change - 
push ENTER.  Now you can view the current setting for 
the option and/or change it. Push ENTER to save your 
changes and activate the option.  See the "MENU 
NAVIGATION" diagram for additional details. 
 
There are 7 operation modes: DMX, Color Fade, Color 
Change, Color Select, Manual Level (2 selections), 
Demo and Sound. 
 
The display will default to 

0XXC

,  which  is a display of 

the current LED plate temperature.  The fan on the unit 
will only turn on when temperature is at or above 45° C 
and turns off at or below 34° C. 

 
DMX OPERATION 
 

Use the 

AXXX

 menu to set the starting address of the 

unit.  You can set the starting address of the unit with 
the UP and DOWN buttons. 
 
For DMX operation the FXLD618FR2I  fixture can be 
configured as a 1, 2, 3, 4, or 5 channel unit. 
 
Set the 

CHXX

 menu to 

01

 (1 channel), 

02 

(2 channel), 

03 

(3 channel), 

04 

(4 channel), or 

05 

(5 channel).

 

 
Detailed information on DMX channel operation is 
given in the tables DMX VALUES AND FUNCTIONS. 
 
The unit has an LED on the menu display (decimal 
point).  If the LED is flashing, the unit is NOT receiving 
signal either from a DMX controller or from a master 
fixture. LED will disappear once DMX is present. 

 
MANUAL OPERATION 
 

If there is no DMX signal provided to the unit,  then 
setting any of these will result in the unit that was set 
acting as a master.  DMX overrides all manual settings.  

 

 
COLOR FADE (CFXX) 
 

The Color Fade mode cycles smoothly through 3 
preset color temperature settings.  Use the 

CFXX

 

menu to set the speed and activate the option.  The 
range is from 0 to 99 with 99 as the fastest. 

 
COLOR CHANGE (CCXX) 
 

The color change mode cycles through 3 preset color 
temperature settings at a user defined speed. Use the 

CCXX 

menu to set the rate of speed at which the 

colors change. The range is from 0 to 99 with 99 as the 
fastest. 

 
COLOR SELECT (CSXX) 

 
For additional manual operations,  you can use the 
Color Select menu (

CSXX

) to select one of three 

preset color temperature settings. 
  

Warm White/Cool White MANUAL LEVEL 
CONTROL 

 
Individual color levels can be controlled manually using 
the 

u000 

(warm  white),

 

and

  E000

  (cool  white)  menus.  

Use the UP and DOWN buttons to change the level, 
then push ENTER when done. The range is 000 - 255. 
 

DEMO MODE (dENo) 

 
The Demo mode is a stand-alone mode designed to 
test the unit.  The Demo mode will not work if the unit 
is receiving DMX.  Exit Demo mode by entering 
Channel mode menu option or insert a DMX signal. 
 

SOUND MODE (Soun) 
 

The unit reacts to sounds by cycling  through three 
preset color temperatures. There are no other settings 
within this mode. 

 
Dimmer Delay (dEL0) 

 
The operation of this function has been discontinued. 
 

MAINTENANCE AND REPAIR 

 

 
 
 
 
 
 
 

CAUTION DO NOT OPEN UNIT  

RISK OF ELECTRIC SHOCK 

RISK OF FIRE 

Reviews: