Lightronics FXLD354WAI Owner'S Manual Download Page 2

 
                               

 

 

 

Page 

 

of 

 

 

 

 

 

 

 

 

 

 

 

 

 

FXLD354WAI LED FIXTURE 

 

Version 0.1  

 

 

 

 

 

 

 

 

 

OWNERS MANUAL   

 

 

 

 

 

 

 

 

       

07/07/2011 

www.lightronics.com 
Lightronics 

Inc. 

        509 

Central 

Drive 

 

Virginia 

Beach, 

Va 

 

234354 

        

 

 

757 

486 

3588

 

DMX TERMINATION 

 

A DMX chain should be terminated at the last 
receiving device on the chain.  This is done by 
installing a commonly available 1/4 Watt, 120 Ohm 
resistor across the DATA - and DATA + wires at the 
last device.  If you have only a few fixtures very close 
together and a very short run to the controller then you 
may be able to operate without the terminator. 

 

OPERATION 

 

A control panel on one side of the unit is used to set the 
operating options.  It consists of an LED display and 
four buttons 

(MENU, UP, DOWN, and ENTER)

 

 
 
 
 

 
 
 
 
 
 
 

Push 

MENU

 to access the operating options. Then use 

UP

 

and 

DOWN

 to scroll through the available choices.  

When you reach the option you want to set or change - 
push 

ENTER

.

  Now you can view the current setting 

for the option and/or change it. Push 

ENTER

 to save 

your changes and activate the option.  See the "MENU 
NAVIGATION" diagram for additional details. 

 

There are 8 operation modes:  DMX, White Level, 
Warm White Level, IP Address, Test Colors, Auto 
Sequence, Run Program, and Slave Mode. 

 

DMX OPERATION 

 

Use the 

d - - -

 

menu to set the starting address of the 

unit.  You can set the starting address of the unit with 
the 

UP

 and 

DOWN

 buttons. 

 

The fixture uses eight channels with allocations as 
follows: 

 

CHANNEL 1:   Master Dimmer  
CHANNEL 2:   Strobe Rate Control 
CHANNEL 3:  Warm White Level 
CHANNEL 4:  White Level 
CHANNEL 5:  Color Macro - Color Combinations 

CHANNEL 6:  Auto Program 
CHANNEL 7:  Auto Program Speed

 

CHANNEL 8:  IP Address 

 

Additional detail on DMX channel operation is given 
in the table "DMX Values and Functions". 

 

MANUAL OPERATION 

 

For manual operation the white, and warm white LED 
levels may be independently controlled. Use the 

Co - -

 

(white) and 

CA - - 

(warm white) menus to set the 

levels.  The range is from 00 (OFF) to 30 (Full On). 

 

IP ADDRESS OPERATION 

 

IP addressing allows you to control individual fixtures 
with the same DMX address  in an independent manner 
without changing the DMX address at the fixture. 

 

An IP address (00 - 85) is first set at the fixture. If set 
to 00 then the fixture IP addressing is deactivated. 

 

The console IP channel (channel 10) can then be used 
to select  fixtures which have a specific IP address.  At 
that point only fixtures which match the console IP 
setting will respond to the other console channels. 

 

If the console IP address selection (channel 10) is 
set to 000 then all IP functions are turned off and 
fixtures will respond according to their DMX address. 

 

TEST COLORS 

 

The Test Colors option runs all LEDs at the level 
selected in its menu.  Use the 

E - - -

 menu to set the 

level.  The range is from 000 to 255.  255 is maximum. 

 

AUTO SEQUENCE 

 

The AUTO SEQUENCE  mode switches continuously 
through a sequence of all the preset programs .  See  
the RUN PROGRAM  menu for more details. Use the 

Au - -

 

 menu to set the sequence speed  and activate 

the option.  The range is from 00 to 99.  00 is fastest. 

 

RUN PROGRAM 

 

The unit can operate using 55 preset programs.  Preset 
0 is "all off".  Presets 1 through 3 are solid colors.  The 
remaining presets are a variety of changing colors and 
patterns.  Use the 

Pr - -

 menu to select and activate a 

preset program.  The range is from 00 to 55. 