0'
1'
2'
3'
4'
5'
6'
7'
0
Ceiling
8'
49
38
21
12
0
8
5
4
3
58
46
32
28
32
46
58
7'
49
22
29
18
12
8
6
4
59
54
44
40
44
54
59
6'
0
36
33
25
18
12
8
6
5
48
45
41
39
41
45
48
5'
0
27
25
21
16
12
9
7
5
39
38
37
36
37
39
39
4'
0
21
20
17
14
11
8
7
5
33
32
32
31
32
32
33
3'
0
16
16
14
12
0
9
8
6
5
28
28
28
28
28
28
28
2'
0
13
13
12
10
0
9
7
6
5
25
24
24
24
24
24
25
1'
0
11
10
10
0
9
0
8
6
6
5
21
21
21
21
21
21
21
Floor
INDIVIDUAL WALMASTER
MULTIPLE UNITS
Walmaster
WMRL143120SO
Page 2 of 2
High Performance, 4', Recessed Wallwasher/Accent Light
One T8 Lamp
Lightolier
a Genlyte Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 a Genlyte company
Section5/Folio K10-17 Rev. A
Job Information
Type:
Ordering Information
Explanation of Catalog Number. Example: WMRL143120S0GLR
Options/Accessories
Fusing
: Internal fast-blow fusing. Suffix:
GLR
.
Internal slow-blow fusing. Suffix:
GMF
.
Radio Interference Filter:
To order one RIF per fixture, Suffix:
R
.
To order one RIF per ballast, Suffix:
B
.
Electrical/Wiring Options
: Consult factory.
Fluorescent Emergency Lighting System:
Factory-installed emergency power
battery pack with charger and inverter.
Suffix:
EM
.
Drywall Frame:
Catalog Number:
WL4DF/UNV
.
Specifications
Materials: Chassis parts
are die-formed 20 gauge cold rolled steel with
integral adjustable hanger clamp.
Reflectors
–
low iridescent semi-specular
aluminum are standard.
Finish: Chassis exterior
–phosphate undercoating, baked white acrylic
enamel.
Reflector
–low iridescent semi-specular IS standard.
Electrical:
Rapid start HPF,
thermally protected class “P” ballast (Biax type).
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels:
I.B.E.W./UL and ULc Listed.
Photometry
Model No. WMRL143120SO
WM
Walmaster:
Low iridescent
semi-specular
wallwash
R
Recessed
L
Reflector:
L
= Low iridescent
semi-specular
aluminum
1
Lamp
4
Length:
4
=48"
3
Watts:
3
=32 Watts
Voltage:
120 or 277
UNV
=120-277
Ballast Type:
<
20THD
<
10THD
1 Lamp Electronic (T8)
SO*
H
I
*
LOL T8 Dimming
PS*
*
–
*Instant Start Standard
NOTE:
For
T8 UNV
, you must use
H
I
Ballast Code.
Options:
Add appropriate
suffix to catalog
no, ie: (GLR)
LER = FP - 53.6 IW - 31.5 BF - 0.85
Comparative yearly lighting energy cost per 1000 lumens = $4.46
coefficients of utilization — zonal cavity method
RF
20
20
20
RC
80
50
30
RW
70
50
30
50
30
10
50
30
10
1
76
73
69
68
66
64
65
63
62
2
69
63
58
59
55
52
57
54
51
3
63
55
49
52
47
44
50
46
43
4
57
49
43
46
41
37
45
40
37
5
53
44
37
41
36
32
40
35
32
6
49
39
33
37
32
28
36
31
28
7
45
36
29
34
29
25
33
28
25
8
42
33
27
31
26
22
30
25
22
9
39
30
24
29
24
20
28
23
20
10
37
28
22
26
22
18
26
21
18
room cavity ratio
FOOTCANDLES ON WALL
Fixtures 3 feet from wall to outside trim on lamp side of fixture
optional drywall frame WL4DF/UNV.
6'
0'
1'
2'
3'
4'
5'
6'
7'
8'
0
Ceiling
8'
53
41
26
18
16
18
26
41
53
50
59
68
59
51
59
68
59
50
7'
52
46
34
26
23
26
34
46
52
67
71
76
72
69
72
76
71
67
6'
41
38
32
26
24
26
32
38
41
60
63
65
64
63
64
65
63
52
5'
32
30
27
25
24
25
27
30
32
52
54
55
55
55
55
55
53
52
4'
25
25
24
22
21
22
24
25
25
46
46
47
47
48
47
46
46
46
3'
21
21
20
20
19
20
20
21
21
38
39
40
40
41
40
40
39
38
2'
18
18
18
17
17
17
18
18
18
33
34
35
35
35
35
35
34
33
1'
15
15
15
15
15
15
15
15
15
28
29
30
30
30
30
30
29
28
Floor
MULTIPLE UNITS
CONTINUOUS ROW
8'