0'
1'
2'
3'
4'
5'
6'
7'
8'
0
Ceiling
8'
111.
101.
75.5
47.8
28.3
18.1
13.2
10.4
0.87
124.
119.
104.
95.4
104.
119.
124.
7'
113.
104.
81.7
55.7
35.5
23.5
16.6
12.5
09.8
130.
127.
117.
111.
117.
127.
130.
6'
86.4
81.0
66.9
49.8
34.8
24.6
17.7
13.4
10.4
104.
106.
102.
100.
102.
106.
104.
5'
62.5
59.1
51.4
41.6
31.9
24.3
18.4
13.9
16.7
81.1
83.5
83.2
83.2
83.2
83.4
81.1
4'
50.5
48.6
42.9
35.6
28.7
22.6
18.0
14.3
11.1
68.8
71.3
71.6
71.3
71.6
71.3
68.8
3'
39.7
38.5
34.9
30.0
25.1
20.6
16.9
14.1
11.4
56.8
59.2
60.0
59.9
60.0
59.2
56.8
2'
31.1
30.3
28.1
25.0
21.7
18.5
15.7
13.4
11.1
47.0
48.8
49.7
50.0
49.7
48.8
47.0
1'
24.2
23.6
22.5
20.8
18.7
16.5
14.6
12.8
11.0
38.8
40.2
41.1
41.5
41.1
40.2
38.8
Floor
INDIVIDUAL WAL-LYTER
MULTIPLE UNITS
Wal-Lyter
WLRN244120SB
Page 2 of 2
High Performance, 4', Recessed Wallwasher/Accent Light
Two Twin Tube T5 Lamps
Lightolier
a Genlyte Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 a Genlyte company
Section5/Folio K10-12 Rev. A
Job Information
Type:
Ordering Information
Explanation of Catalog Number. Example: WLRN244120SBGLR
Options/Accessories
Fusing
: Internal fast-blow fusing. Suffix:
GLR
.
Internal slow-blow fusing. Suffix:
GMF
.
Lens:
.187, pattern 19 lens. Catalog Number:
WLRKIT-4 CSP
to be field installed.
Radio Interference Filter:
To order one RIF per fixture, Suffix:
R
.
To order one RIF per ballast, Suffix:
B
.
Electrical/Wiring Options
: Consult factory.
Fluorescent Emergency Lighting System:
Factory-installed emergency power
battery pack with charger and inverter.
Suffix:
EM
.
Drywall Frame:
Catalog Number:
WL4DF/UNV
.
Specifications
Materials: Chassis parts
are die-formed 20 gauge cold rolled steel with
integral adjustable hanger clamp.
Reflectors
–
low iridescent specular aluminum are
standard.
Finish: Chassis exterior
–phosphate undercoating, baked white acrylic
enamel.
Reflector
–low iridescent specular is standard.
Lens:
Virgin acrylic .187 pattern 19 with square based male conical prisms
(rotates for easy lamp replacement).
Electrical:
Rapid start HPF,
thermally protected class “P” ballast (Biax type). If K.O.
is within 3" of ballast, use wire suitable for at least 90°.
Labels:
I.B.E.W./UL and ULc Listed.
Photometry
Model No. WLRN244120SB
WL
Wal-Lyter:
Low iridescent
specular
wallwash
R
Recessed
Reflector:
N
= Low iridescent
specular aluminum
standard
K
= Pattern 19 virgin
acrylic lens
installed at factory
2
Lamps
4
Length:
4
=48"
Watts:
1
=18 Watts
2
=24 Watts
4
=40 Watts
5
=50 Watts
6
=55 Watts
Voltage:
120 or 277
Options:
Add appropriate
suffix to catalog
no, ie: (GLR)
LER = FP - 47.5 IW - 85 BF - 0.95
Comparative yearly lighting energy cost per 1000 lumens = $5.05
coefficients of utilization — zonal cavity method
RF
20
20
20
RC
80
50
30
RW
70
50
30
50
30
10
50
30
10
1
73
70
67
65
63
61
63
61
59
2
66
61
56
57
53
50
55
52
49
3
60
53
47
50
45
42
48
44
41
4
55
47
40
44
39
35
42
38
35
5
50
41
34
39
33
29
37
33
29
6
46
36
30
34
29
25
33
28
25
7
42
32
26
31
25
21
30
25
21
8
38
29
22
27
22
18
26
21
18
9
35
25
19
24
19
15
23
19
15
10
32
23
17
22
17
13
21
16
13
room cavity ratio
FOOTCANDLES ON WALL
Fixtures 3 feet from wall to outside trim on lamp side of fixture
6'
0'
1'
2'
3'
4'
5'
6'
7'
8'
0
Ceiling
8'
120.
111.
88.6
65.7
56.5
65.8
88.6
111.
120.
181.
182.
183.
183.
184.
183.
183.
182,
181.
7'
124.
117.
98.4
79.0
70.9
79.1
98.4
117.
124.
200.
201.
203.
203.
203.
203.
203.
201.
200.
6'
97.7
94.8
84.7
74.4
69.6
74.4
84.7
94.8
97.7
173.
175.
176.
177.
177.
177.
176.
175,
173.
5'
74.1
73.5
69.9
66.0
63.8
66.0
69.9
73.5
74.1
143.
146.
147.
148.
148.
148.
147.
146.
143.
4'
62.6
63.4
61.2
58.3
57.3
58.3
61.1
63.4
62.6
125.
128.
129.
130.
130.
130.
129.
128.
125.
3'
51.9
53.0
52.1
50.6
50.2
50.6
52.0
53.1
51.9
108.
110.
111.
112.
113.
112.
111.
110.
108.
2'
43.0
44.1
43.9
43.4
43.2
43.4
43.9
44.0
43.0
91.9
03.0
05.2
05.9
96.3
95.9
95.2
93.9
91.9
1'
35.7
36.6
37.0
37.2
37.2
37.2
37.0
36.6
35.7
78.7
80.3
81.4
82.1
82.5
82.0
81.4
80.3
78.7
Floor
MULTIPLE UNITS
CONTINUOUS ROW
8'
Ballast Type:
<
20THD
<
10THD
2 Lamp Magnetic (TT5)
BX*
–
(40 Watt)
2 Lamp Electronic (TT5)
BA
*
–
(18 Watt)
2 Lamp Electronic (TT5)
BB
*
–
(24 Watt)
2 Lamp Electronic (TT5)
SB*
I
B*
(40 Watt)
2 Lamp Electronic (TT5)
BE
*
BP
(50 Watt)
2 Lamp Electronic (TT5)
–
*
BF
(55 Watt)
LOL (TT5) Dimming
PB*
*
–
(40 Watt)
*Instant Start Standard
optional drywall frame WL4DF/UNV.