background image

Wal-Lyter

WLRN124120SB

Page 2 of 2

High Performance, 2', Recessed Wallwasher/Accent Light

One Twin Tube T5 Lamp

Lightolier 

a Genlyte Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 a Genlyte company

Section5/Folio K10-10 Rev. A

Job Information

Type:

Ordering Information

Explanation of Catalog Number. Example: WLRN124120SBGLR

Options/Accessories

Fusing

: Internal fast-blow fusing. Suffix: 

GLR

.

Internal slow-blow fusing. Suffix: 

GMF

.

Lens: 

.187, pattern 19 lens. Catalog Number: 

WLRKIT CSP 

(to be field installed).

Radio Interference Filter: 

To order one RIF per fixture,Suffix: 

R

To order one RIF per ballast, Suffix: 

B

.

Electrical/Wiring Options

: Consult factory.

Fluorescent Emergency Lighting System: 

Factory-installed emergency power bat-

tery pack with charger and inverter. 

Suffix: 

EM

.

Drywall Frame: 

Catalog Number: 

WL2DF/UNV

.

Specifications

Materials: Chassis parts

are die-formed 20 gauge cold rolled steel with

integral adjustable hanger clamp. 

Reflectors

low iridescent specular aluminum are

standard.

Finish: Chassis exterior

–phosphate undercoating, baked white acrylic

enamel. 

Reflector

–low iridescent specular IS standard. 

Lens: 

Virgin acrylic .187 pattern 19 with square based male conical prisms

(rotates for easy lamp replacement).

Electrical: 

Rapid start HPF,

thermally protected class “P” ballast (Biax type). If K.O.

is within 3" of ballast, use wire suitable for at least 90°.

Labels:

I.B.E.W./UL and ULc Listed.

Photometry

Model No. WLRN124120SB

WL

Wal-Lyter:

Low iridescent

specular

wallwash

R

Recessed

N

Reflector:

N

= Low iridescent

specular aluminum
standard

1

Lamps

2

Length:

2

=24"

Watts:

1

=18 Watts

2

=24 Watts

4

=40 Watts

5

=50 Watts

6

=55 Watts

Voltage:

120 or 277

Ballast Type:

<

20THD

<

10THD

1 Lamp Magnetic (TT5)

BX*

(40 Watt)

1 Lamp Electronic (TT5)

BA

*

(18 Watt)

1 Lamp Electronic (TT5)

BB

*

(24 Watt)

1 Lamp Electronic (TT5)

SB*

I

B*

(40 Watt)

1 Lamp Electronic (TT5)

BE

*

BP

(50 Watt)

1 Lamp Electronic (TT5)

-

*

BF

(55 Watt)

LOL (TT5) Dimming

PB*

*

(40 Watt)

*Instant Start Standard

Options:

Add appropriate

suffix to catalog

no, ie: (GLR)

LER = FP - 42.8  IW - 47   BF - 0.95
Comparative yearly lighting energy cost per 1000 lumens = $5.61

coefficients of utilization — zonal cavity method  

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

74

71

68

66

64

62

64

62

60

2

67

61

57

58

54

51

55

52

49

3

61

54

48

51

46

42

49

45

41

4

56

47

41

49

39

35

43

38

35

5

51

41

35

39

34

29

38

33

29

6

46

37

30

35

29

25

33

29

25

7

42

32

26

31

25

21

30

25

21

8

39

29

23

27

22

18

26

22

18

9

35

26

19

24

19

15

24

19

15

10

33

23

17

22

17

13

21

16

13

room cavity ratio

0'

1'

2'

3'

4'

5'

6'

7'

8'

0

4'

6'

0'

1'

2'

3'

4'

5'

6'

7'

8'

Ceiling

8'

76

67 48

25

14

0

8

5

4

3

107 104 102 104 107

86

79

63

50

63 79

86

204 204 209 208 212 208 209 204 204

7'

64

68 48

29

17

10

7

5

4

102 104 106 104 102

78

75

67

58

67 75

78

201 203 208 208 212 208 208 203 201

6'

47

44 36

24

17

12

8

6

4

0

85

0

86

0

88

0

86

0

85

63

62

57

48

57 62

63

165 166 173 172 177 172 173 166 165

5'

33

34 29

24

14

10

8

6

5

0

66

0

74

0

74

9

74

0

66

49

50

48

48

48 50

49

132 142 140 148 145 148 140 142 132

4'

26

28 23

23

14

11

8

6

5

0

59

0

65

0

62

0

65

0

59

42

45

42

40

42 45

42

113 124 121 130 126 130 121 124 113

3'

19

21 29

17

12

9

8

6

5

0

48

0

53

0

56

0

53

0

48

35

36

37

34

37 36

35

0

96 100 104 106 109 106 104 100 096

2'

15

16 15

13

11

9

8

6

5

0

42

0

44

0

46

0

44

0

42

31

31

31

26

31 31

31

0

80

0

82

0

88

0

88

0

93

0

88

0

88

0

82

0

80

1'

13

12 11

11

10

8

7

6

5

0

38

0

37

0

36

0

37

0

38

27

26

26

22

26 26

27

0

67

0

68

0

74

0

74

0

79

0

74

0

74

0

68

0

67

Floor

INDIVIDUAL WAL-LYTER

MULTIPLE UNITS

CONTINUOUS ROW

FOOTCANDLES ON WALL  

Fixtures 3 feet from wall to outside trim on lamp side of fixture

optional drywall frame WL2DF/UNV.