VIDEO TELECONFERENCE LUMINAIRE
VTS2GPK3FT
Page 2 of 2
2'x2' RECESSED FLUORESCENT
Lightolier
a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
SECTION 5/Folio K05-10
Job Information
Type:
OPTIONS & ACCESSORIES
RADIO INTERFERENCE FILTER
120 or 277 volt, 50 or 60 Hz. One per fixture.
SUFFIX:
RF
.
ELECTRICAL/WIRING OPTIONS
Consult factory.
DRYWALL KIT:
Order Catalog Number:
FK92X2
. (Request Folio OA30-10).
CHICAGO PLENUM:
SUFFIX:
CP
.
SPECIFICATIONS
MATERIALS: Chassis parts
are die formed code gauge cold rolled steel.
Housing
side rails hemmed over and housing ends turned-in for safe handling.
Parabolic Blades
–pre-anodized specular aluminum (Coilzak® or equal).
Lens
–High quality glare control lens with square based male conical prisms.
FINISH: Chassis exterior
–black baked polyester enamel.
Cavity
–white
baked polyester enamel minimum 86% reflectance. Phosphate undercoating.
ELECTRICAL:
Thermally protected class “P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS:
I.B.E.W./UL and ULc listed.
PHOTOMETRY
MODEL NO. VTS2GPK3FT120X3
coefficients of utilization — zonal cavity method
(effective floor cavity reflectance 0.20)
RF
20
20
20
RC
80
50
30
RW
70
50
30
50
30
10
50
30
10
1
62
60
59
57
55
54
55
54
53
2
58
55
52
52
50
48
50
49
47
3
54
50
47
48
45
43
46
44
42
4
51
46
42
44
41
39
43
40
38
5
48
42
38
40
37
35
39
37
34
6
45
39
35
37
34
31
36
33
31
7
42
36
32
35
31
29
34
31
29
8
39
33
29
32
29
26
31
28
26
9
37
31
27
30
27
24
29
26
24
10
35
29
25
28
25
22
27
24
22
visual comfort probability
(rated lumens per lamp 3150.)
room size
ceiling height
ceiling height
W
L
8.5
10.0
13.0
16.0
8.5
10.0
13.0
16.0
20
20
94
92
89
81
82
77
76
75
20
30
95
93
92
85
84
78
72
70
20
40
96
93
92
87
86
80
73
69
20
60
96
94
93
85
87
82
76
70
30
20
94
91
89
81
82
79
80
76
30
30
95
92
91
85
86
80
75
71
30
40
95
93
91
85
88
83
76
69
30
60
95
93
93
85
89
84
79
70
30
80
95
94
93
85
89
86
81
70
40
20
94
92
90
81
83
79
80
79
40
30
95
92
92
85
86
80
77
74
40
40
96
93
92
85
99
93
78
72
40
60
96
94
93
85
89
85
80
73
40
80
95
94
93
85
90
86
82
73
40
100
95
94
94
85
90
87
84
73
60
30
95
93
92
85
86
80
77
74
60
40
96
93
92
86
88
83
78
72
60
60
96
94
93
86
90
85
81
74
60
80
95
94
93
86
90
87
83
75
60
100
95
94
94
86
90
88
85
75
100
40
96
93
92
87
88
83
78
73
100
60
96
94
92
87
90
86
81
74
100
80
95
94
93
87
91
88
84
75
100
100
95
94
94
87
91
89
85
76
room cavity ratio
luminaries lengthwise
luminaries crosswise
ORDERING INFORMATION
Explanation of Catalog Number. Example: VTS2GPK3FT120X3GLR
Other dimming options. Consult factory.
LER = FP - 42.9
WATTS - 102.6
BF - 0.85
Comparative yearly lighting energy cost per 1000 lumens = $5.59
VT
VT:
Video
Teleconference
Luminaire
S
BODY STYLE:
S
=Static
2
FIXTURE
WIDTH
CEILING TYPE:
G
= Grid
(lay-in T bar)
T
= Slot Grid
PK
INTEGRATED
SHIELDING
LAMP
QUANTITY
2
=2 Lamp
3
=3 Lamp
LAMP TYPE/
FIXTURE
LENGTH:
6U
=6"U Lamp T8
(2 Lamp Only)
FT
=Twin Tube T5
(Nominal 24")
VOLTAGE:
120 or 277
OPTIONS:
Add appropriate
suffix to catalog
no, ie: (
GLR
)
BALLAST TYPE:
<
20THD
<
10THD
1 & 2 Lamp Elec. T8
SO*
H
I
*
1 & 2 Lamp Elec. TT5
SB*
I
B*
(40 watt)
1-3 Lamp Elec. T8
O3*
H3*
1-3 Lamp Elec. TT5
X3*
I
3*
(40 watt)
LOL T8 Dimming
PS
–
LOL TT5 Dimming
PB
–
*
Instant Start Standard
Blank
=Standard
N
=NYC Code
G02032
VTS2GPK3FT120X3