VR PARABOLIC
VRA2G18LP332
Page 2 of 2
2'x4' RECESSED FLUORESCENT, 4" DEEP, 18 CELL (3x6) PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE
Lightolier
a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
SECTION 2/Folio G05-64 REV. A
Job Information
Type:
OPTIONS & ACCESSORIES
PLASTER FRAME:
Catalog Number:
PF24
.
CONTINUOUS ROW INSTALLATION:
For F type fixtures, half-width flanges are
required between fixtures, Order Catalog Number:
S2FCTRIM
(each joint).
SPLAY TRIM:
For T ceiling type only. SUFFIX:
CTZ24 S2 SPLAY TRIM
.
RADIO INTERFERENCE FILTER:
120 or 277 volt, 50 or 60 Hz. One per fixture
standard. SUFFIX:
RF
.
ELECTRICAL WIRING OPTIONS:
Consult factory.
AIR CLOSURE STRIP:
SUFFIX
ACS4
(factory installed).
DRYWALL KIT:
Order Catalog Number:
FK92X4
. Request Folio OA30-10.
CHICAGO PLENUM:
SUFFIX:
CP
.
SPECIFICATIONS
PERFORMANCE:
In an installation of 3 lamp 32W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less
than .70 with a spacing to mounting ratio of 1.4 perpendicular to the lamps. To
meet IES RP1 recommended (basic) requirements for VDT areas the VCP (visual
comfort probability) shall not be less than 94 either crosswise or lengthwise and
the maximum average brightness at 65°, 75° and 85° shall not exceed 304, 147,
and 0 candelas per square meter respectively in the 0°, 45°, and 90° horizontal
planes.
SPECIFICATIONS (continued)
AIR HANDLING:
(VRA only) side air passages for air supply or air return.
Optional side closure strips. Air return is also provided through the lamp com-
partment through fixture body ends.
MATERIALS: Chassis parts
are die-formed embossed cold rolled steel.
Housing
side rails hemmed over and housing ends turned-in for safe handling.
LOUVER:
Pre-anodized aluminum (Coilzak@ or equal).
FINISH: Chassis exterior
–black baked polyester enamel.
Cavity
–white baked
polyester enamel minimum 86% reflectance. Phosphate undercoating.
Louver
–low iridescence semi-specular anodized vertical grain aluminum reflec-
tor sheet is standard.
ELECTRICAL:
Thermally protected class “P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS:
I.B.E.W./UL and C-UL.
PHOTOMETRY
MODEL NO. VRA2G18LP332O3
coefficients of utilization — zonal cavity method
(effective floor cavity reflectance 0.20)
RF
20
20
20
RC
80
50
30
RW
70
50
30
50
30
10
50
30
10
1
72
70
68
66
65
63
64
62
61
2
67
64
60
60
58
56
58
56
54
3
63
58
54
55
52
49
53
51
48
4
58
52
48
50
46
44
49
46
43
5
54
48
43
46
42
39
45
41
38
6
51
44
39
42
38
35
41
37
35
7
47
40
35
38
34
31
38
34
31
8
44
37
32
35
31
28
35
31
28
9
42
34
29
33
29
26
32
28
26
10
39
31
27
30
26
24
30
26
24
visual comfort probability
(rated lumens per lamp 3150.)
room size
ceiling height
ceiling height
W
L
8.5
10.0
13.0
16.0
8.5
10.0
13.0
16.0
20
20
90
86
79
79
98
96
97
93
20
30
92
88
83
78
98
97
97
94
20
40
92
89
86
81
98
97
97
94
20
60
93
90
87
83
98
97
97
94
30
20
90
86
84
82
98
97
97
92
30
30
92
89
86
81
98
97
97
94
30
40
93
90
88
83
98
97
97
94
30
60
93
91
89
85
98
97
97
94
30
80
93
91
90
86
98
97
97
94
40
20
90
86
84
85
98
97
97
92
40
30
93
90
86
84
98
97
97
93
40
40
93
91
88
84
98
97
97
93
40
60
94
91
90
86
98
97
97
94
40
80
94
91
90
87
98
97
97
94
40
100
94
91
90
88
98
97
97
94
60
30
93
90
86
83
98
97
97
93
60
40
93
91
89
84
98
97
97
93
60
60
94
92
90
87
98
97
97
94
60
80
94
92
90
88
98
97
97
94
60
100
94
92
91
88
98
97
97
94
100
40
93
91
89
84
98
97
97
94
100
60
94
92
90
87
98
97
97
94
100
80
94
92
91
88
98
97
97
95
100
100
93
92
91
89
97
97
97
95
room cavity ratio
luminaries lengthwise
luminaries cr
osswise
ORDERING INFORMATION
Explanation of Catalog Number. Example: VRA2G18LP332120SOGLR
LER = FP - 55.0
WATTS - 85
BF - 0.85
Comparative yearly lighting energy cost per 1000 lumens = $4.36
VR
VR:
4" Deep
Pre-anodized
Aluminum
Louver
For Normal
VDT Use
BODY STYLE:
A=
Air Handling
S
=Static
2
FIXTURE
WIDTH
CEILING TYPE:
G
= Grid
(lay-in T bar)
F
=Flanged
(overlap)
Z spline and
plaster frame
T
=Slot grid or
two-directional
concealed T
(see options)
18
NUMBER OF
CELLS:
(3 rows of
6 cells)
LOUVER
FINISH*:
L
=Low
Iridescence
Semi-specular
(standard)
P
=Low
Iridescence
Specular
P
DUAL “V”
REFLECTOR
3
LAMP
QUANTITY
LAMP TYPE/
FIXTURE
LENGTH:
32
=T8
34
=T12
VOLTAGE:
120 or 277
OPTIONS:
Add appropriate
suffix to catalog
no, ie: (
GLR
)
BALLAST TYPE:
1 & 2 Lamp Mag.
LE
<
20THD
<
10THD
1 & 2 Lamp Elec. T8
SO*
H
I
*
1-3 Lamp Elec. T8
O3*
H3*
LOL T8 Dimming
PS
–
*
Instant Start Standard
Other dimming options. Consult factory.