STACKLYTE
STA 1'x4' 2 LAMP
Page 2 of 2
1'x4' RECESSED FLUORESCENT, 3" DEEP, 8 OR 12 CELL PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE
Lightolier
a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
Section 2/Folio G40-16 REV. A
Job Information
Type:
OPTIONS & ACCESSORIES
ACCESS PLATE:
Top Wiring access plate is shipped with fixture as standard.
When access plates are required in advance for wiring convenience, specify sepa-
rately. Order Catalog Number:
ACP CSP
.
ELECTRICAL WIRING OPTIONS:
Consult factory.
FUSING:
Internal fast-blow fusing. SUFFIX:
GLR
.
Internal slow-blow fusing. SUFFIX:
GMF
.
RADIO INTERFERENCE FILTER:
120 or 277 volt, 50 or 60 Hz. One per fixture
standard. SUFFIX:
RF
.
SPLAY TRIM:
For T ceiling type only. SUFFIX:
CTZ14
.
PLASTER FRAMES:
F type fixtures do not include plaster frames. For individual
or continuous mounting, specify
PF14
universal frame per fixture.
AIR CLOSURE STRIPS:
SUFFIX
ACS4
(factory installed).
DRYWALL KIT:
Order Catalog Number:
FK91X4
. Request Folio OA30-10.
CHICAGO PLENUM:
SUFFIX:
CP
.
SPECIFICATIONS
PERFORMANCE:
Luminaire distribution is to be a minimum of 97.5% in the 0°-
60° zone. In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1,
reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .80
with a spacing to mounting ratio of 1.6 perpendicular to the lamps. To meet IES RP1
recommended (basic) requirements for VDT areas the VCP (visual comfort probabili-
ty) shall not be less than 90 either crosswise or lengthwise, and the maximum
SPECIFICATIONS (continued)
average brightness at 65°, 75° and 85° shall not exceed 617, 191 and 162 can-
delas per square meter respectively in the 0°, 45° and 90° horizontal planes.
AIR HANDLING:
(STA only) side air passages for air supply or air return.
Optional side closure strips. Air return is also provided through the lamp com-
partment through fixture body ends.
MATERIALS: Chassis parts
are die-formed embossed cold rolled steel.
Housing
is embossed for rigidity with all edges turned-in for safe handling.
LOUVER:
Pre-anodized aluminum (Coilzak® or equal).
FINISH: Louver
—semi-specular low iridescence pre-anodized reflector sheet.
Reflector
—95% reflective specular. Phosphate undercoating.
Chassis exterior
—black baked polyester enamel.
ELECTRICAL:
Thermally protected class “P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS:
I.B.E.W./UL and C-UL.
PHOTOMETRY
MODEL NO. STA1G8LR232120SO
coefficients of utilization — zonal cavity method
RF
20
20
20
RC
80
50
30
RW
70
50
30
50
30
10
50
30
10
1
77
74
72
70
68
67
67
66
65
2
71
67
64
64
61
59
61
59
57
3
66
61
56
58
54
52
56
53
51
4
62
55
50
53
49
46
51
48
45
5
57
50
45
48
44
41
47
43
40
6
53
46
40
44
40
36
43
39
36
7
50
42
37
40
36
33
39
35
32
8
47
38
33
37
33
29
36
32
29
9
44
35
30
34
30
27
34
30
27
10
41
33
28
32
27
24
31
27
24
room cavity ratio
ORDERING INFORMATION
Explanation of Catalog Number. Example: STA1G8LR232120SOGLR
To meet NYC Code requirements prefix catalog number
with (N).
BLANK
= Standard
N
= NYC Code
ST
STACKLYTE:
3" Deep
Precision
Contoured
Pre-
anodized
Aluminum
Louver
BODY STYLE:
A=
Air Handling
S
=Static
1
FIXTURE
WIDTH
CEILING TYPE:
G
= Grid (lay-in T bar)
F
=Flanged (overlap)
Z spline and
plaster frame
T
=Slot grid or
two-directional
concealed T
(see options)
NUMBER OF
CELLS:
8
=1 row of
8 cells
12
=1 row of
12 cells
LOUVER
FINISH:
L
=Low
Iridescence
Semi-specular
(standard)
P
=Low iridescence
specular
R
REFLECTOR:
R
=Specular
95%
Reflective
2
LAMP
QUANTITY
LAMP/
FIXTURE LENGTH:
32
=T8
34
=T12
(Nominal 48")
VOLTAGE:
120 or 277
OPTIONS:
Add appropriate
suffix to catalog
no, ie: (GLR)
VERTICAL FOOTCANDLES ON BOOK SHELVES
Ceiling
1'
2'
3'
4'
1.00
84.9
85.1
85.2
85.0
84.8
85.0
85.1
85.1
84.9
2.00
64.5
63.9
64.1
64.2
64.3
64.2
64.1
63.8
64.5
3.00
50.1
50.2
50.1
50.1
50.2
50.1
50.1
50.2
50.1
4.00
41.3
41.2
41.3
41.3
41.3
41.3
41.3
41.2
41.2
5.00
36.8
36.7
36.8
36.7
36.7
36.7
36.8
36.7
36.8
6.00
32.1
32.1
32.1
32.1
32.1
32.1
32.1
32.1
32.1
7.00
28.9
28.9
28.9
28.9
28.9
28.9
28.9
28.9
28.9
8.00
27.5
27.5
27.5
27.5
27.4
27.5
27.5
27.5
27.5
9.00
25.9
25.8
25.8
25.8
25.8
25.8
25.8
25.8
25.9
10.00
23.9
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
11.00
21.1
21.1
21.1
21.1
21.1
21.1
21.1
21.1
21.1
12.00
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
0'
1'
2'
3'
4'
Book shelf aisle width, 36"
Floor
LER = FL - 55.0
IW - 61.9
BF - 0.88
Comparative yearly lighting energy cost per 1000 lumens = $4.36
BALLAST TYPE:
1 Lamp Mag. T12
LE
<20THD <10THD
1 Lamp Elec. T8
SO*
H
I
*
LOL Dimming
PS
–
*
Instant Start Standard