Specplus

SPS2GFSVA32U or 317

Page 2 of 2

2' x 2' Recessed Fluorescent, Lens Frame Troffer

Static, 2 or 3 Lamp T8, 1-5/8"U or 2' Lamp

Ordering Information

Explanation of Catalog Number. Example: SPS2GFSVA32UUNVH3

Options/Accessories

Special Lenses

: Substitute

VY

for

VA

(standard) = .125" nominal pattern 12 with 7.8 oz. average weight

per square foot. Substitute

VI

for

VA

(standard) = .125" nominal pattern 12 with 6.8 oz. average weight per

square foot. Substitute

S1

or

S2

for

VA

(standard) = Sky Acrylic Lens (see Sky Lens sell sheet for

further details).

Plaster Frame

: Catalog Number:

PF22

.

Continuous Row Installation

: For F type fixtures, half width flanges are required between

fixtures. Order Catalog Number:

2FC TRIM CSP

(each joint).

Radio Interference Filter

: To order one RIF per fixture; SUFFIX:

R

.

To order one RIF per ballast; SUFFIX:

B

.

Fusing

: Internal fast-blow fusing. SUFFIX

A

.

Internal slow-blow fusing. SUFFIX

C

.

Electrical Wiring Options

: Consult factory.

Drywall Kit

: Order Catalog Number:

FK92X2

. (Request Folio OA30-10 Rev. A).

Chicago Plenum

: SUFFIX:

C

.

Specifications

Performance

: In an installation of 3 lamp 31W luminaires in a room cavity ratio of 1, reflectance

80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .72. To prevent glare the VCP shall
be not less than 35 either lengthwise or crosswise (at 100fc level) and the average brightness at 65°
shall not exceed 3497 candelas per square meter. To control veiling reflections, luminaire output in
the 30°-90° zone shall not be less than 66.8%.

Specifications (continued)

Materials

:

Chassis parts

are die-formed code gauge cold rolled steel. Housing with side rails hemmed

over and housing ends turned-in for safe handling.

Finish

:

Chassis exterior

–black baked polyester enamel.

Cavity

–white baked polyester enamel

minimum 86% reflectance. Phosphate undercoating.

Lenses

:

VA

(standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the

panel edge, .095" nominal thickness (similar to pattern 12).

VY

(optional) .125" nominal pattern 12

with 7.8 oz. average weight per square foot.

VI

(optional) .125" nominal pattern 12 with 6.8 oz. aver-

age weight per square foot.

Electrical

: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of

ballast, use wire suitable for at least 90°.

Labels

: I.B.E.W. UL and ULc Listed.

This product may have a mercury containing lamp.
Manage in accord with Disposal Laws. See: www.lamprecycle.org

Specplus:

Recessed

fluorescent

troffer

S

Static

2

Fixture

Width

Lens Frame:

FS

= Flat steel

frame.

RA

= Regressed

aluminum

frame.

FA

= Flat aluminum

frame.

Lens Shielding

Type:

VA

=Virgin acrylic

(standard)

S1

=Sky lens 1

S2

=Sky lens 2

See options and

consult factory

Lamp

Quantity

2

=2 Lamp

3

=3 Lamp

Ballast Type:

<

20THD

<

10THD

1 & 2 Lamp Elec. T8

SO *

H

I

*

1–3 Lamp Elec. T8

O3 *

H3 *

LOL T8 Dimming

PS

*Instant Start Standard
Other dimming options. Consult factory.

NOTE:

For

T8 UNV

, you must use

H

I

,

H3

Ballast Code.

Options:

Add appropriate suffix

to catalog no., ie: (A)

Voltage:

120, 277 or

UNV

=120-277

Lamp Type/

Fixture Length:

2U

=T8, 1-5/8"U Lamp

17

=T8, 2' Lamp

(Nominal 24")

Note:

For

Linear

T5 Lamp

option,

consult factory

SP

Standard Specplus Plus

SX

For NYC Code – Local 3 Manufactured

Ceiling Type:

G

= Grid

(lay-in T bar)

F

= Flanged (over

lap) Z spline and
plaster frame

0.0

45.0

90.0

FLUX

0

2391

2391

2391

5

2376

2376

2382

226

15

2269

2289

2315

647

25

2056

2106

2160

971

35

1728

1799

1877

1126

45

1277

1361

1467

1051

55

786

840

909

755

65

434

411

460

434

75

219

201

264

244

85

82

87

109

98

90

0

0

0

Model No. SPS2GFSVA32U12003

LER = FP - 64.1

IW - 76.2

BF - 0.88

Comparative yearly lighting energy cost per

1000 lumens = $3.74

Report Number: G00057
Catalog Number: SPS2GFSVA32U12003
Lamps: (3) U6T8
Luminaire: 2' x 2' SpecPlus with regressed

aluminum door frame and extruded
virgin acrylic shielding .095" nominal
thickness (similar to pattern 12).

Ballast: REL-3P32-SC
Report is based on 2725 Lumens per lamp.
Efficiency: 67.9%
CIE Type-Direct-Indirect
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.3

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

21.875

21.875

CANDELA DISTRIBUTION

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

5803.

6184.

6666.

55

4403.

4705.

5092.

65

3300.

3125.

3497.

75

2719.

2495.

3277.

85

3023.

3207.

4018.

LUMINANCE DATA IN CANDELA/SQ. METER

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

0

1 75 72 69 67 65 63 65 63 62

0

2 69 63 59 60 57 54 58 55 53

0

3 63 56 51 53 49 46 52 48 45

0

4 58 51 45 48 44 40 46 43 39

0

5 54 46 40 43 39 35 42 38 35

0

6 50 41 36 39 35 31 38 34 31

0

7 46 38 32 36 31 28 35 31 28

0

8 43 34 29 33 28 25 32 28 25

0

9 40 32 26 31 26 23 30 26 23

10 38 29 24 28 24 21 28 24 21

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

1844

22.6

33.2

0

0-

0

40

2970

36.3

53.5

0

0-

0

60

4776

58.4

86.0

0

0-

0

90

5552

67.9

100.0

90-180

000

0

0.0

00

0.0

0

0-180

5552

67.9

100.0

ZONAL LUMEN SUMMARY

Job Information

Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

02/10

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group

Section 1A/Folio E60-24 Rev. B

Photometry

Sky Lens Options

S1

S2

Reviews: