background image

SL205C

Decorative, Spectral, Floating Paper, Optic Forms

Page 3 of 3

Philips Lightolier

e: [email protected]

t:  (508) 679-8131

w: www.lightolier.com
SL205C  February 23, 2012
Specifications are subject to change without notice. 

© Koninklijke Philips Electronics N.V., 2012. All rights reserved.

Job Information 

Type:

Report No: LSC8924

Cat. No: SL205BTEU

1 x 42W TTT at 3200 lumens

Efficiency:42.3% 

Spacing Ratio: 1.2

60°

30°

413

550

275

180º

90°

13

8

Room Ca

vity Ratio

Coefficients Of Utilization - Zonal Cavity Method

Effective Floor Cavity Reflectance = .20

RC

80

70

50

30

10

0

RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10

0

 

0

.50 .50 .50 .50 .49 .49 .49 .49 .47 .47 .47 .45 .45 .45 .43 .43 .43 .42

1

.47 .45 .43 .42 .46 .44 .43 .41 .42 .41 .40 .40 .40 .39 .39 .38 .38 .37

2

.43 .40 .38 .35 .42 .39 .37 .35 .38 .36 .34 .37 .35 .34 .35 .30 .33 .32

3

.40 .36 .33 .30 .39 .35 .32 .30 .34 .32 .30 .33 .31 .29 .32 .30 .29 .28

4

.37 .32 .29 .26 .36 .32 .29 .26 .31 .28 .26 .30 .27 .26 .29 .27 .25 .24

5

.34 .29 .26 .23 .33 .29 .25 .23 .28 .25 .23 .27 .24 .22 .26 .24 .22 .21

6

.31 .26 .23 .20 .31 .26 .23 .20 .25 .22 .20 .24 .22 .20 .24 .21 .20 .19

7

.29 .24 .20 .18 .28 .23 .20 .18 .23 .20 .18 .22 .19 .17 .22 .19 .17 .17

8

.27 .22 .18 .16 .26 .21 .18 .16 .21 .18 .16 .20 .18 .16 .20 .17 .15 .15

9

.25 .20 .16 .14 .24 .19 .16 .14 .19 .16 .14 .18 .16 .14 .18 .16 .14 .13

10

.23 .18 .15 .13 .23 .18 .15 .13 .17 .14 .12 .17 .14 .12 .17 .14 .12 .12

Determined in accordance with current IES published procedures

Luminaire input watts = 48.2

Candlepower summary

Angle Mean Lumens

0

556

5

555

54

10

553

15

540

152

20

515

25

484

222

30

448

35

406

253

40

362

45

315

242

50

260

55

225

201

60

184

65

140

139

70

99

75

65

70

80

38

85

16

19

90

3

Zonal Lumens and Percentages

Zone Lumens %Lamp %Fixt

0-30

427

13.36

31.60

0-40

680

21.28

50.33

0-60

1124

35.15

83.14

0-90

1352

42.28 100.00

40-90

671

21.00

49.67

60-90

228

7.13

16.86

90-180

0

0.00

0.00

0-180

1352

42.28 100.00

ROOM SURFACE REFLECTANCES

80% Ceiling; 50% Wall; 20% Floor

3200 Lumens Per Lamp

RCR = 1

 (Rm. width = 10 x mtg. ht. above work plane)

RCR = 5

 (Rm. width = 2 x mtg. ht. above work plane)

RCR = 10

 (Rm. width = mtg. ht. above work plane)

 20 

40 

60 

80 

100 

120 

140

This quick calculator chart determines the number and spacing of 1 lt. - 42W TTT units 

with Clear Alzak reflector, for any level of illumination.

AREA PER FIXTURE IN SQUARE FEET

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

INITIAL FOO

TCANDLES

60

50

40

30

20

10

Quick Calculator

4 5 6 7  8  9 

10 

11 

12 

Reviews: